Finger tip carboxyhemoglobin saturation monitor.. A CO-oximeter is a device that measures the oxygen carrying state of hemoglobin in a blood specimen, including oxygen-carrying hemoglobin (O2Hb), non-oxygen-carrying but normal hemoglobin (HHb) (formerly, but incorrectly, referred to as 'reduced' hemoglobin), as well as the dyshemoglobins such as carboxyhemoglobin (COHb) and methemoglobin (MetHb).
In addition to the total concentration of hemoglobin, the oxygen saturation will define the concentration of oxy- and deoxyhemoglobin in tissue and so the total absorption spectrum. Depending on the type of tissue, we can consider different situations. Below, the total concentration of hemoglobin is assumed to be 2.3 mM.
Other methods which propose to measure neural activity directly have been attempted (for example, measurement of the Oxygen Extraction Fraction, or OEF, in regions of the brain, which measures how much of the oxyhemoglobin in the blood has been converted to deoxyhemoglobin [3]), but because the electromagnetic fields created by an active or ...
In the oxygen-rich capillaries of the lung, this property causes the displacement of carbon dioxide to plasma as low-oxygen blood enters the alveolus and is vital for alveolar gas exchange. The general equation for the Haldane Effect is: H + + HbO 2 ⇌ H + Hb + O 2; However, this equation is confusing as it reflects primarily the Bohr effect.
Visible light absorbers (λ = 400 to 700 nm) include oxyhemoglobin, deoxyhemoglobin, melanin, and cytochrome c. Visible light photoacoustic microscopy is particularly useful in determining hemoglobin concentration and oxygen saturation due to the difference in absorption profiles of oxyhemoglobin and deoxyhemoglobin.
Specifically, the oxyhemoglobin dissociation curve relates oxygen saturation (SO 2) and partial pressure of oxygen in the blood (PO 2), and is determined by what is called "hemoglobin affinity for oxygen"; that is, how readily hemoglobin acquires and releases oxygen molecules into the fluid that surrounds it. Structure of oxyhemoglobin
The SaO2 calculation in the arterial blood gas analysis is falsely normal, as it is calculated under the premise of hemoglobin either being oxyhemoglobin or deoxyhemoglobin. However, co-oximetry can distinguish the methemoglobin concentration and percentage of hemoglobin. [ 3 ]
An SaO 2 (arterial oxygen saturation) value below 90% causes hypoxia (which can also be caused by anemia). Hypoxia due to low SaO 2 is indicated by cyanosis, but oxygen saturation does not directly reflect tissue oxygenation. The affinity of hemoglobin to oxygen may impair or enhance oxygen release at the tissue level.