ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
ASHRAE 90.1 follows a similar path of development and revision. [6] Though ASHRAE 90.1 is revised and published every three years just like the IECC, people can submit interim revisions at any time within this period. [5] ASHRAE has a standards committee that manages the process, and votes on the final versions of the energy code. [5]
The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) provides lighting standards in ASHRAE 90.1-2004. EPAct of 2005 set a deadline for states to adopt the ASHRAE 90.1-2004 standards. [19] ASHRAE has recently published the 90.1-2010 with improved lighting standards, this includes:
Space By Space Method. A defined list of many possible space types within a building the associated watts per square foot allowance. For example, ANSI/ASHRAE/IESNA Standard 90.1-2007 allows the Emergency Space of a hospital to be designed for 2.7 watts per square foot, but the Recovery areas of a hospital would be allowed 0.8 watts per square foot.
ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]
The following is a list of U.S. based energy codes and standards that reference building simulations to demonstrate compliance: ASHRAE 90.1; International Energy Conservation Code (IECC) Leadership in Energy and Environmental Design (LEED) Green Globes; California Title 24; EnergyStar Multifamily High rise Program; Passive House Institute US ...
It has its own set of criteria for assessment and utilizes the ASHRAE codes and standards. Due to its simplicity and ease-of-use, the LEED quickly gained international recognition within a short period. [1] Over the years, LEED has undergone many changes and is now currently in its fourth iteration, which was launched in late 2013. [26]
There are two major systems to classify ductwork airtightness, one based on European standards, the other based on ASHRAE standard 90.1-2010.Both are based on the leakage airflow rate at a given ductwork pressure divided by the product of the ductwork surface area and the same ductwork pressure raised to the power 0.65.