The fire point, or combustion point, of a fuel is the lowest temperature at which the liquid fuel will continue to burn for at least five seconds after ignition by an open flame of standard dimension. [1] At the flash point, a lower temperature, a substance will ignite briefly, but vapour might not be produced at a rate to sustain the fire ...
This allows the development of an equilibrium between the liquid and the air volume. The ignition source is directed into the cup at regular intervals with simultaneous interruption of stirring. The test concludes upon observation of a flash that spreads throughout the inside of the cup. The corresponding temperature is the liquid's flash point.
The Cleveland open-cup method is one of three main methods in chemistry for determining the flash point of a petroleum product using a Cleveland open-cup apparatus, also known as a Cleveland open-cup tester. [1] First, the test cup of the apparatus (usually brass) is filled to a certain level with a portion of the product.
The TAG flash point tester adheres to ASTM D56 and has no stirrer, while the Abel flash point testers adheres to IP 170 and ISO 13736 and has a stirring motor so the sample is stirred during testing. The flash point is an empirical measurement rather than a fundamental physical parameter.
A fire test can be conducted to determine the degree of flammability. Test standards used to make this determination but are not limited to the following: Underwriters Laboratories UL 94 Flammability Testing; International Electrotechnical Commission IEC 60707, 60695-11-10 and 60695-11-20; International Organization for Standardization ISO 9772 ...
Any liquid with a flash point greater than 35 °C (95 °F) and with a fire point greater than 100 °C (212 °F) according to ISO 2592. Any liquid with a flash point greater than 35 °C (95 °F) which is in a water-miscible solution with a water content of more than 90 percent by mass.
Liquids having a flash point below 22.8 °C (73 °F) and having a boiling point at or above 37.8 °C (100 °F) or having a flash point between 22.8 and 37.8 °C (73 and 100 °F). 4 Will rapidly or completely vaporize at normal atmospheric pressure and temperature, or is readily dispersed in air and will burn readily (e.g., gasoline , acetylene ...
Lower flammability limit (LFL): The lowest concentration (percentage) of a gas or a vapor in air capable of producing a flash of fire in the presence of an ignition source (arc, flame, heat). The term is considered by many safety professionals to be the same as the lower explosive level (LEL).