Percutaneous umbilical cord blood sampling (PUBS), also called cordocentesis, fetal blood sampling, or umbilical vein sampling is a diagnostic genetic test that examines blood from the fetal umbilical cord to detect fetal abnormalities. [1] Fetal and maternal blood supply are typically connected in utero with one vein and two arteries to the fetus.
Particularly, umbilical cord blood gas analysis can give an indication of preceding fetal hypoxic stress. In combination with other clinical information, normal paired arterial and venous cord blood gas results can usually provide a robust defence against a suggestion that an infant had an intrapartum hypoxic-ischaemic event. [2]
Fetal scalp blood testing for lactate became well-known in the 1990s. One study has shown that there is a correlation between both umbilical cord pH and lactate measurement in fetus arterial blood. [13] From a physiological standpoint, lactate levels in tissues earlier increase before pH decreases in oxygenation deficiency.
The fetal circulation is composed of the placenta, umbilical blood vessels encapsulated by the umbilical cord, heart and systemic blood vessels. A major difference between the fetal circulation and postnatal circulation is that the lungs are not used during the fetal stage resulting in the presence of shunts to move oxygenated blood and ...
Acid–base imbalance is an abnormality of the human body's normal balance of acids and bases that causes the plasma pH to deviate out of the normal range (7.35 to 7.45). In the fetus, the normal range differs based on which umbilical vessel is sampled (umbilical vein pH is normally 7.25 to 7.45; umbilical artery pH is normally 7.18 to 7.38). [1]
Delaying the clamping allows blood to flow from the placenta to the baby while the baby’s lungs fill with air. ... Waiting at least two minutes before clamping the umbilical cord of a premature ...
In the fetus, the lungs are not used for ventilation. Instead, the placenta performs ventilatory functions (gas exchange). Fetal respiratory acidemia is defined as an umbilical vessel pH of less than 7.20 and an umbilical artery PCO 2 of 66 or higher or umbilical vein PCO 2 of 50 or higher. [3]
Histopathology of placenta with increased syncytial knotting of chorionic villi, with two knots pointed out. The following characteristics of placentas have been said to be associated with placental insufficiency, however all of them occur in normal healthy placentas and full term healthy births, so none of them can be used to accurately diagnose placental insufficiency: [citation needed]