Electric power quality is the degree to which the voltage, frequency, and waveform of a power supply system conform to established specifications. Good power quality can be defined as a steady supply voltage that stays within the prescribed range, steady AC frequency close to the rated value, and smooth voltage curve waveform (which resembles a sine wave).
The System Average Interruption Duration Index (SAIDI) [1] is commonly used as a reliability index by electric power utilities. SAIDI is the average cumulative outage duration for each customer served, and is calculated as:
A voltage sag (U.S. English) or voltage dip [1] (British English) is a short-duration reduction in the voltage of an electric power distribution system. It can be caused by high current demand such as inrush current (starting of electric motors, transformers, heaters, power supplies) or fault current (overload or short circuit) elsewhere on the system.
These include voltage sags, dips and swells, transient overvoltages, flicker, high-frequency noise, phase imbalance and poor power factor. [29] Power quality issues occur when the power supply to a load deviates from the ideal. Power quality issues can be especially important when it comes to specialist industrial machinery or hospital equipment.
Dynamic voltage restoration (DVR) is a method of overcoming voltage sags and swells that occur in electrical power distribution. [1] [2] [3] These are a problem because spikes consume power and sags reduce efficiency of some devices. DVR saves energy through voltage injections that can affect the phase and wave-shape of the power being supplied ...
The power system reliability (sometimes grid reliability) is the probability of a normal operation of the electrical grid at a given time. Reliability indices characterize the ability of the electrical system to supply customers with electricity as needed [ 1 ] by measuring the frequency, duration, and scale of supply interruptions. [ 2 ]
A switched-mode power supply will be affected if the brownout voltage is lower than the minimum input voltage of the power supply. As the input voltage falls, the current draw will increase to maintain the same output voltage and current, until such a point that the power supply malfunctions or its under-voltage protection kicks in and disables ...
The Customer Average Interruption Duration Index (CAIDI) is a reliability index commonly used by electric power utilities. [1] It is related to SAIDI and SAIFI, ...