Ads
related to: residual current breaker requirements
Search results
Results from the WOW.Com Content Network
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.
To eliminate this confusion, the IEC decided to apply the term residual current device (RCD) to differential-current-operated ELCBs. Residual current refers to any residue when comparing current in the outbound and return currents in the circuit. In a single phase circuit this is simply the live or phase current minus the neutral current. In a ...
To provide supplementary protection against high-impedance faults it is common to recommend a residual-current device (RCD) also known as a residual current circuit breaker (RCCB), ground fault circuit interrupter (GFCI), or residual current operated circuit-breaker with integral over-current protection (RCBO), which will cut off the supply of ...
IEC 61009 Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) IEC 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use; IEC 61012 Filters for the measurement of audible sound in the presence of ultrasound
For low-voltage distribution circuit breakers an international standard, IEC 60898-1, defines rated current as the maximum current that a breaker is designed to carry continuously. The commonly available preferred values for rated current are 1 A, 2 A, 4 A, 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A, [ 6 ] and 125 A.
Most GFCI receptacles allow the connection and provide GFCI protection for down-stream connected receptacles. Receptacles protected in this manner or with a GFCI circuit breaker should be labeled "GFCI protected". (Outside North America these are referred to as a "Residual-current device" or RCD.)
New sections have been added relating to microgeneration and solar photovoltaic systems [verification needed], and breakers (including high resilience breaker layout). [verification needed] 2018 18th IET/BSI Introduced energy efficiency performance levels and the use of surge protection devices and arc fault detection devices. [10] Issued with ...
Retrieved from "https://en.wikipedia.org/w/index.php?title=Residual-current_circuit_breaker&oldid=41774014"
Ads
related to: residual current breaker requirements