The international standard IEC 60446 Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors was a standard published by the International Electrotechnical Commission (IEC) that defined basic safety principles for identifying electrical conductors by colours or numerals, for example in ...
In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V or 120v. Countries such as Mexico may adopt the NFPA standard as their national electrical code, with local amendments similar to those ...
The cable core colours are described in IEC 60304 (1982-01), Standard colours for insulation for low- frequency cables and wires. The three-phase phase colours are brown, black and grey instead of red, yellow and blue. Where a circuit includes a neutral or mid-point conductor identified by colour, the colour used shall be blue.
Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]
Household wiring does not usually use three-phase supplies and the clash only occurs in three-phase systems. Wiring to the old standard can be detected by use of a red wire. The new standard colour code does not use red. Where new wiring is mixed with old, cables must be clearly marked to prevent interchange of phase and neutral.
Cable identification colours: [f] (section 3.8.3.4) Multiphase cables [d] Current AS/NZS cables European cables Single-phase cables Current AS/NZS flexible cords, flexible cables and equipment wiring, and European cables Superseded AS/NZS flexible cords Pre-2004 IEE [further explanation needed] United Kingdom until April 2006 (BS 7671) India ...
In the United States it is not usually used for three phase power but for the high leg delta wiring of split-phase electric power (unknown in Europe). This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase.
A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.