Search results
Results from the WOW.Com Content Network
The K Factor also helps calculate the peak-to-daily ratio of traffic. K30 helps maintain a healthy volume to capacity ratio. [3] K50 and K100 will sometimes be seen. K50 and K100 will not use the 30th highest hourly traffic volumes but the 50th or 100th highest hourly traffic volume when calculating the K factor.
K correction converts measurements of astronomical objects into their respective rest frames. The correction acts on that object's observed magnitude (or equivalently, its flux ). Because astronomical observations often measure through a single filter or bandpass, observers only measure a fraction of the total spectrum , redshifted into the ...
The K-factor is the bending capacity of sheet metal, and by extension the forumulae used to calculate this. [1] [2] [3] Mathematically it is an engineering aspect of geometry. [4] Such is its intricacy in precision sheet metal bending [5] (with press brakes in particular) that its proper application in engineering has been termed an art. [4] [5]
K-factor (Elo rating system), a constant used in Elo rating system; K-factor (marketing), the growth rate of websites, apps, or a customer base; K-factor (sheet metal), the ratio of location of the neutral line to the material thickness; The K Factor, a fictional TV show within Harry Hill's TV Burp; Bondi k-factor, the "k" in Bondi k-calculus
Before performing a Yates analysis, the data should be arranged in "Yates' order". That is, given k factors, the k th column consists of 2 (k - 1) minus signs (i.e., the low level of the factor) followed by 2 (k - 1) plus signs (i.e., the high level of the factor). For example, for a full factorial design with three factors, the design matrix is
In centrifugation the clearing factor or k factor represents the relative pelleting efficiency of a given centrifuge rotor at maximum rotation speed. It can be used to estimate the time t {\displaystyle t} (in hours) required for sedimentation of a fraction with a known sedimentation coefficient s {\displaystyle s} (in svedbergs ):
The system stiffness matrix K is square since the vectors R and r have the same size. In addition, it is symmetric because k m {\displaystyle \mathbf {k} ^{m}} is symmetric. Once the supports' constraints are accounted for in (2), the nodal displacements are found by solving the system of linear equations (2), symbolically:
Pressure and temperature sensors providing pulses can be used to determine mass flow, with division of the pulses by the K-factor, or multiplication with the inverse of the K-factor providing factored totalization, and rate indication. Furthermore, by dividing the pulse rate by the K-Factor, the volumetric throughput per unit time of the rate ...