enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Potentiometric titration - Wikipedia

    en.wikipedia.org/wiki/Potentiometric_titration

    Reference electrodes generally used are hydrogen electrodes, calomel electrodes, and silver chloride electrodes. The indicator electrode forms an electrochemical half-cell with the interested ions in the test solution. The reference electrode forms the other half-cell. The overall electric potential is calculated as

  3. Electroanalytical methods - Wikipedia

    en.wikipedia.org/wiki/Electroanalytical_methods

    Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition. Therefore, the difference in ...

  4. Ion-selective electrode - Wikipedia

    en.wikipedia.org/wiki/Ion-selective_electrode

    An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a simple membrane-based potentiometric device which measures the activity of ions in solution. [1] It is a transducer (or sensor ) that converts the change in the concentration of a specific ion dissolved in a solution into an electrical potential .

  5. Potentiometer (measuring instrument) - Wikipedia

    en.wikipedia.org/wiki/Potentiometer_(measuring...

    One form of potentiometer is a uniform high-resistance wire attached to an insulating support, marked with a linear measuring scale. In use, an adjustable regulated voltage source E, of greater magnitude than the potential to be measured, is connected across the wire so as to pass a steady current through it.

  6. Reference electrode - Wikipedia

    en.wikipedia.org/wiki/Reference_electrode

    Most electrodes work over a limited range of conditions, such as pH or temperature, outside of this range the electrodes behavior becomes unpredictable. The advantage of a pseudo-reference electrode is that the resulting variation is factored into the system allowing researchers to accurately study systems over a wide range of conditions.

  7. Total ionic strength adjustment buffer - Wikipedia

    en.wikipedia.org/wiki/Total_ionic_strength...

    Total ionic strength adjustment buffer (TISAB) is a buffer solution which increases the ionic strength of a solution to a relatively high level. This is important for potentiometric measurements, including ion selective electrodes , because they measure the activity of the analyte rather than its concentration.

  8. Determination of equilibrium constants - Wikipedia

    en.wikipedia.org/wiki/Determination_of...

    When a glass electrode is used to obtain the measurements on which the calculated equilibrium constants depend, the precision of the calculated parameters is limited by secondary effects such as variation of liquid junction potentials in the electrode. In practice it is virtually impossible to obtain a precision for log β better than ±0.001.

  9. Bulk electrolysis - Wikipedia

    en.wikipedia.org/wiki/Bulk_electrolysis

    One contains the auxiliary and working electrode, while the other contains the reference electrode. Strictly speaking, the reference electrode does not require a separate compartment. A Quasi-Reference Electrode such as a silver/silver chloride wire electrode can be exposed directly to the analyte solution. In such situations there is concern ...