The variable (V) domain of light chains has a high degree of structural diversity, particularly the antigen-binding region. In addition, the first 23 amino acids of the 1st variable domain framework region have a number of variations known as subgroups. Four kappa (Vκ1–Vκ4) and six lambda subgroups (Vλ1–Vλ6) can be identified. [1]
Once set, light chain class remains fixed for the life of the B lymphocyte. In a healthy individual, the total kappa-to-lambda ratio is roughly 2:1 in serum (measuring intact whole antibodies) or 1:1.5 if measuring free light chains, with a highly divergent ratio indicative of neoplasm. The free light chain ratio ranges from 0.26 to 1.65. [1]
In the Immunology Medical Lab, two types of tests can be run: "end point nephelometry" and "kinetic (rate) nephelometry". End point nephelometry tests are run by allowing the antibody/antigen reaction to run through to completion (until all of the present reagent antibodies and the present patient sample antigens that can aggregate have done so ...
The panel simultaneously tests 4 patients (one in each quadrant). Each patient has 6 electrophoresis panels: The left one is a conventional serum protein electrophoresis . The remainder get solutions with anti-IgG, anti-IgA, anti-IgM, anti-kappa light chain and anti-lambda light chain immunoglobulin, respectively from left to right.
Light chain deposition disease can affect any organ. [3] Renal involvement is always present and can be identified by microscopic hematuria and proteinuria.Due to the gradual buildup of light chains from plasma filtration, renal function rapidly declines in the majority of patients with LCDD as either acute tubulointerstitial nephritis or rapidly progressing glomerulonephritis.
In practice, this is inferred by the detection of only one of the mutually exclusive antibody light chains, kappa or lambda, on the entire population of the abnormal B cells. Normal B lymphocytes consist of a stew of different antibody-producing cells, resulting in a mixture of both kappa- and lambda-expressing cells.
A new approach to a routine blood test could predict a person’s 30-year risk of heart disease, research published Saturday in the New England Journal of Medicine found.
Light chain MGUS is defined as a disorder in which a serum κ to λ free light chain ratio falls outside the normal range of 0.26–1.65 (mean =0.9) provided that it is not associated with: a) any of the CRAB criteria, b) a bone marrow plasma cell count of 10 or a higher percentage of nucleated cells, c) evidence of amyloid deposition (see ...