Example of a spent fuel pool from the shut-down Caorso Nuclear Power Plant. This pool is not holding large amounts of material. Spent fuel pools (SFP) are storage pools (or "ponds" in the United Kingdom) for spent fuel from nuclear reactors. They are typically 40 or more feet (12 m) deep, with the bottom 14 feet (4.3 m) equipped with storage ...
The fuel cladding is the first layer of protection around the nuclear fuel and is designed to protect the fuel from corrosion that would spread fuel material throughout the reactor coolant circuit. In most reactors it takes the form of a sealed metallic or ceramic layer.
The five criteria for ECCS are to prevent peak fuel cladding temperature from exceeding 2200 °F (1204 °C), prevent more than 17% oxidation of the fuel cladding, prevent more than 1% of the maximum theoretical hydrogen generation due the zircalloy metal-water reaction, maintain a coolable geometry, and allow for long-term cooling.
Spent nuclear fuel, occasionally called used nuclear fuel, is nuclear fuel that has been irradiated in a nuclear reactor (usually at a nuclear power plant). It is no longer useful in sustaining a nuclear reaction in an ordinary thermal reactor and, depending on its point along the nuclear fuel cycle , it will have different isotopic ...
The time required for the fuel to melt. After the water has boiled, then the time required for the fuel to reach its melting point will be dictated by the heat input due to decay of fission products, the heat capacity of the fuel and the melting point of the fuel. The time required for the molten fuel to breach the primary pressure boundary.
[citation needed] The containment is the fourth and final barrier to radioactive release (part of a nuclear reactor's defence in depth strategy), the first being the fuel ceramic itself, the second being the metal fuel cladding tubes, the third being the reactor vessel and coolant system. [2]
As a nuclear fuel bundle increases in burnup (time in reactor), the radiation begins changing not only the fuel pellets inside the cladding, but the cladding material itself. The zirconium chemically reacts to the water flowing around it as coolant, forming a protective oxide on the surface of the cladding.
A fuel element failure is a rupture in a nuclear reactor's fuel cladding that allows the nuclear fuel or fission products, either in the form of dissolved radioisotopes or hot particles, to enter the reactor coolant or storage water. [1] The de facto standard nuclear fuel is uranium dioxide or a mixed uranium/plutonium dioxide.