PACs are deployed in SCADA systems to provide RTU and PLC functions. In many electrical substation SCADA applications, "distributed RTUs" use information processors or station computers to communicate with digital protective relays, PACs, and other devices for I/O, and communicate with the SCADA master in lieu of a traditional RTU.
DF-1 - used by Allen-Bradley ControlLogix, CompactLogix, PLC-5, SLC-500, and MicroLogix class devices; DNP3 - a protocol used to communicate by industrial control and utility SCADA systems; DirectNet – Koyo / Automation Direct proprietary, yet documented PLC interface; EtherCAT; Ethernet Global Data (EGD) – GE Fanuc PLCs (see also SRTP)
The DNP3 protocol is also referenced in IEEE Std. IEEE 1379-2000, which recommends a set of best practices for implementing modern SCADA Master-RTU/IED communication links. These include not just encryption but other practices that enhance security against well known intrusion methods.
A feedback control loop is directly controlled by the RTU or PLC, but the SCADA software monitors the overall performance of the loop. For example, a PLC may control the flow of cooling water through part of an industrial process to a set point level, but the SCADA system software will allow operators to change the set points for the flow.
A programmable logic controller (PLC) or programmable controller is an industrial computer that has been ruggedized and adapted for the control of manufacturing processes, such as assembly lines, machines, robotic devices, or any activity that requires high reliability, ease of programming, and process fault diagnosis.
Most IEDs have a communication port and built-in support for standard communication protocols (DNP3, IEC104 or IEC61850), so they can communicate directly with the SCADA system or a substation programmable logic controller. Alternatively, they can be connected to a substation RTU that acts as a gateway towards the SCADA server. [2]
A remote terminal unit (RTU) is a microprocessor-controlled electronic device that interfaces objects in the physical world to a distributed control system or SCADA (supervisory control and data acquisition) system by transmitting telemetry data to a master system, and by using messages from the master supervisory system to control connected objects. [1]
Determinacy involves assuring that each device is guaranteed access to the network, and in many cases mechanisms to allow priority information (such as alarms) through the system. Compatibility allows SCADA and Distributed Control Systems (DCS) from various manufacturers to communicate with control and measurement equipment from others.