The hemocytometer (or haemocytometer, or Burker's chamber) is a counting-chamber device originally designed and usually used for counting blood cells. [ 1 ] The hemocytometer was invented by Louis-Charles Malassez and consists of a thick glass microscope slide with a rectangular indentation that creates a precision volume chamber.
A counting chamber. A counting chamber, is a microscope slide that is especially designed to enable cell counting. Hemocytometers and Sedgewick Rafter counting chambers are two types of counting chambers. The hemocytometer has two gridded chambers in its middle, which are covered with a special glass slide when counting.
This type of hematology analyzer utilizes both Coulter's principle and flow cytometry to determine the granularity, diameter, and inner complexity of the cells. Using hydrodynamic focusing, the cells are sent through an aperture one cell at a time. During this, a laser is directed at them, and the scattered light is measured at multiple angles.
Through the work of Karl von Vierordt, Louis-Charles Malassez, Karl Bürker and others blood cell concentration could by the late 19th century be accurately measured using a blood cell counting chamber, the hemocytometer, and an optical microscope. [3] [4] Until the 1950s the hemocytometer was the standard method to count blood cells. [5]
A complete blood count (CBC), also known as a full blood count (FBC), is a set of medical laboratory tests that provide information about the cells in a person's blood.The CBC indicates the counts of white blood cells, red blood cells and platelets, the concentration of hemoglobin, and the hematocrit (the volume percentage of red blood cells).
A Coulter counter [3] is one of the other devices used for cell counting. Like CASY technology, this also uses electric current for cell counting. However, the difference between them is that there is an aperture called “sensing zone”, with a known volume of electrolyte in a coulter counter.
Celloscope automated cell counter was developed in the 1950s for enumeration of erythrocytes, leukocytes, and thrombocytes in blood samples. [1] Together with the Coulter counter, the Celloscope analyzer can be considered one of the predecessors of today's automated hematology analyzers, as the principle of the electrical impedance method is still utilized in cell counters installed in ...
Coulter principle — the transient current drop is proportional to the particle volume The tip of the Coulter counter in a buffer solution, counting cells in solution.. A Coulter counter [1] [2] is an apparatus for counting and sizing particles suspended in electrolytes.