enow.com Web Search

  1. Ads

    related to: bathroom fan cfm requirements calculator
  2. supplyhouse.com has been visited by 100K+ users in the past month

    • Refrigerant Line Sets

      Shop Our Selection of Flared and

      Standard Line Sets at Low Prices.

    • HVAC Tools

      From Brands Including Fieldpiece,

      Malco, Bacharach, and More.

Search results

  1. Results from the WOW.Com Content Network
  2. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  3. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Q = Volumetric flow rate of air in cubic feet per minute (cfm) Vol = Space volume L × W × H, in cubic feet; In metric units = where: ACPH = number of air changes per hour; higher values correspond to more ventilation; Q = Volumetric flow rate of air in liters per second (L/s)

  4. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    To further confuse the issue, a centrifugal fan is a constant CFM device or a constant volume device. This means that, provided the fan speed remains constant, a centrifugal fan will pump a constant volume of air. This is not the same as pumping a constant mass of air. Again, the fan will pump the same volume, though not mass, at any other air ...

  5. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    Fan airflow is determined using C Fan and n Fan values that are provided by the blower door manufacturer, and they are used to calculate Q Fan. The multi-point blower door test procedure results in a series of known values of Q n, Fan and ∆P n, Building. Typical ∆P n, Building values are ±5, 10, 20, 30, 40 and 50 pascal.

  6. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    As more architecture incorporated mechanical ventilation, the cost of outdoor air ventilation came under some scrutiny. In 1973, in response to the 1973 oil crisis and conservation concerns, ASHRAE Standards 62-73 and 62–81) reduced required ventilation from 10 CFM (4.76 L/s) per person to 5 CFM (2.37 L/s) per person. In cold, warm, humid, or ...

  7. Affinity laws - Wikipedia

    en.wikipedia.org/wiki/Affinity_laws

    The affinity laws are useful as they allow the prediction of the head discharge characteristic of a pump or fan from a known characteristic measured at a different speed or impeller diameter. The only requirement is that the two pumps or fans are dynamically similar, that is, the ratios of the fluid forced are the same.

  8. Airwatt - Wikipedia

    en.wikipedia.org/wiki/Airwatt

    Where airflow in Cubic Feet per Minute [CFM] is calculated using airflow = √ 13.35 × D 2 / vacuum. Where D is the diameter of the orifices. [5] [further explanation needed] CFM is always given statistically at its maximum which is at a 2-inch (51 mm) opening. Waterlift, on the other hand, is always given at its maximum: a 0-inch opening.

  9. Specific fan power - Wikipedia

    en.wikipedia.org/wiki/Specific_fan_power

    In reality the fan system efficiency is often in the range 0 to 60% (i.e. <); it is lowest for small fans or inefficient operating points (e.g. throttled flow or free-flow). The efficiency is a function of the total losses in the fan system, including aerodynamic losses in the fan, friction losses in the drive (e.g. belt), losses in the ...