Search results
Results from the WOW.Com Content Network
Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.
Q = Volumetric flow rate of air in cubic feet per minute (cfm) Vol = Space volume L × W × H, in cubic feet; In metric units = where: ACPH = number of air changes per hour; higher values correspond to more ventilation; Q = Volumetric flow rate of air in liters per second (L/s)
To further confuse the issue, a centrifugal fan is a constant CFM device or a constant volume device. This means that, provided the fan speed remains constant, a centrifugal fan will pump a constant volume of air. This is not the same as pumping a constant mass of air. Again, the fan will pump the same volume, though not mass, at any other air ...
Fan airflow is determined using C Fan and n Fan values that are provided by the blower door manufacturer, and they are used to calculate Q Fan. The multi-point blower door test procedure results in a series of known values of Q n, Fan and ∆P n, Building. Typical ∆P n, Building values are ±5, 10, 20, 30, 40 and 50 pascal.
As more architecture incorporated mechanical ventilation, the cost of outdoor air ventilation came under some scrutiny. In 1973, in response to the 1973 oil crisis and conservation concerns, ASHRAE Standards 62-73 and 62–81) reduced required ventilation from 10 CFM (4.76 L/s) per person to 5 CFM (2.37 L/s) per person. In cold, warm, humid, or ...
The affinity laws are useful as they allow the prediction of the head discharge characteristic of a pump or fan from a known characteristic measured at a different speed or impeller diameter. The only requirement is that the two pumps or fans are dynamically similar, that is, the ratios of the fluid forced are the same.
Where airflow in Cubic Feet per Minute [CFM] is calculated using airflow = √ 13.35 × D 2 / vacuum. Where D is the diameter of the orifices. [5] [further explanation needed] CFM is always given statistically at its maximum which is at a 2-inch (51 mm) opening. Waterlift, on the other hand, is always given at its maximum: a 0-inch opening.
In reality the fan system efficiency is often in the range 0 to 60% (i.e. <); it is lowest for small fans or inefficient operating points (e.g. throttled flow or free-flow). The efficiency is a function of the total losses in the fan system, including aerodynamic losses in the fan, friction losses in the drive (e.g. belt), losses in the ...