A 3 dB pad reduces power to one half, 6 dB to one fourth, 10 dB to one tenth, 20 dB to one hundredth, 30 dB to one thousandth and so on. When input and output impedances are the same, voltage attenuation will be the square root of power attenuation, so, for example, a 6 dB attenuator that reduces power to one fourth will reduce the voltage (and ...
In engineering, attenuation is usually measured in units of decibels per unit length of medium (dB/cm, dB/km, etc.) and is represented by the attenuation coefficient of the medium in question. [1] Attenuation also occurs in earthquakes; when the seismic waves move farther away from the hypocenter, they grow smaller as they are attenuated by the ...
Figure 3. A Π-pad attenuator formed from two symmetrical L sections. Because of the symmetry, R 1 = R 3 in this case. For an attenuator, Z and Y are simple resistors and γ becomes the image parameter attenuation (that is, the attenuation when terminated with the image impedances) in nepers. A Π pad can be viewed as being two L sections back ...
Figure 3. A T-pad attenuator formed from two symmetrical L sections. Because of the symmetry, R 1 = R 3 in this case. For an attenuator, Z and Y are simple resistors and γ becomes the image parameter attenuation (that is, the attenuation when terminated with the image impedances) in nepers. A T pad can be viewed as being two L sections back-to ...
[3] Positive ACR calculations mean that transmitted signal strength is stronger than that of near-end crosstalk. [4] ACR can be used to define a signal bandwidth (e.g. 250 MHz for category 6 cable) where signal to noise ratios are sufficient to support certain applications. [4]
The term hybrid coupler originally applied to 3 dB coupled-line directional couplers, that is, directional couplers in which the two outputs are each half the input power. This synonymously meant a quadrature 3 dB coupler with outputs 90° out of phase. Now any matched 4-port with isolated arms and equal power division is called a hybrid or ...
The decibel originates from methods used to quantify signal loss in telegraph and telephone circuits. Until the mid-1920s, the unit for loss was miles of standard cable (MSC). 1 MSC corresponded to the loss of power over one mile (approximately 1.6 km) of standard telephone cable at a frequency of 5000 radians per second (795.8 Hz), and matched closely the smallest attenuation detectable to a ...
The attenuator must have an accurate ratio over the whole range of frequencies of interest; the input impedance of the instrument becomes part of the attenuator. A DC attenuator with resistive divider is supplemented with capacitors, so that the frequency response is predictable over the range of interest.