enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Corneal pachymetry - Wikipedia

    en.wikipedia.org/wiki/Corneal_pachymetry

    Corneal pachymetry is the process of measuring the thickness of the cornea.A pachymeter is a medical device used to measure the thickness of the eye's cornea.It is used to perform corneal pachymetry prior to refractive surgery, for Keratoconus screening, LRI surgery [1] and is useful in screening for patients suspected of developing glaucoma among other uses.

  3. Intraocular lens power calculation - Wikipedia

    en.wikipedia.org/wiki/Intraocular_lens_power...

    The central corneal power is the second important factor in the calculation formula. To simplify the calculation, the cornea is assumed to be a thin spherical lens with a fixed anterior to posterior corneal curvature ratio and an index of refraction of 1.3375. Central corneal power can be measured by keratometry or corneal topography.

  4. Intraocular pressure - Wikipedia

    en.wikipedia.org/wiki/Intraocular_pressure

    Measured values of intraocular pressure are influenced by corneal thickness and rigidity. [5] [6] As a result, some forms of refractive surgery (such as photorefractive keratectomy) can cause traditional intraocular pressure measurements to appear normal when in fact the pressure may be abnormally high. A newer transpalpebral and transscleral ...

  5. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    When the area of a circle with diameter 3.06 mm (0.120 in) has been flattened, the opposing forces of corneal rigidity and the tear film are roughly approximate and cancel each other out allowing the pressure in the eye to be determined from the force applied. Like all non-invasive methods, it is inherently imprecise and may need to be adjusted.

  6. Pellucid marginal degeneration - Wikipedia

    en.wikipedia.org/wiki/Pellucid_marginal_degeneration

    However, it may not be as specific as corneal pachymetry, because corneal topography only evaluates the degree and distribution of surface irregularities on the cornea, not the thickness of the cornea. [5] Corneal topography may show a "crab claw-like" appearance, a finding that is seen in both keratoconus and in pellucid marginal degeneration.

  7. Keratoconus - Wikipedia

    en.wikipedia.org/wiki/Keratoconus

    Pachymetry ≥ 400 μm; Stage 3 Induced myopia and/or astigmatism between 8.01 and 10.00 D; K-reading > 53.00 D; Pachymetry 200 to 400 μm; Stage 4 Refraction not measurable; K-reading > 55.00 D; Central scars; Pachymetry ≤ 200 μm; Stage is determined if one of the characteristics applies. Corneal thickness is the thinnest measured spot of ...

  8. Effects of long-term contact lens wear on the cornea - Wikipedia

    en.wikipedia.org/wiki/Effects_of_long-term...

    Increased corneal curvature is yet another change known to arise from long-term contact lens wear; [1] this increase in corneal curvature can be as much as 0.5 diopters greater than normal. [8] This is thought to be caused by corneal thinning-induced ectasia. [1]

  9. Van Herick technique - Wikipedia

    en.wikipedia.org/wiki/Van_Herick_technique

    The anterior chamber drainage angle is then graded as a ratio between the peripheral anterior chamber depth and corneal thickness (AC : C ratio) [5] or expressed traditionally as a fraction [6] to provide the Van Herick's result. Grading can also be obtained by distinguishing the structures visible upon observation.