  2. Van Deemter equation - Wikipedia

    en.wikipedia.org/wiki/Van_Deemter_equation

    In liquid chromatography, the mobile phase velocity is taken as the exit velocity, that is, the ratio of the flow rate in ml/second to the cross-sectional area of the ‘column-exit flow path.’ For a packed column, the cross-sectional area of the column exit flow path is usually taken as 0.6 times the cross-sectional area of the column.

  3. Resolution (chromatography) - Wikipedia

    en.wikipedia.org/wiki/Resolution_(chromatography)

    Chromatographic peak resolution is given by = + where t R is the retention time and w b is the peak width at baseline. The bigger the time-difference and/or the smaller the bandwidths, the better the resolution of the compounds. Here compound 1 elutes before compound 2.

  4. Resolution (mass spectrometry) - Wikipedia

    en.wikipedia.org/wiki/Resolution_(mass_spectrometry)

    The valley definition defines ΔM as the closest spacing of two peaks of equal intensity with the valley (lowest value of signal) between them less than a specified fraction of the peak height. Typical values are 10% or 50%. The value obtained from a 5% peak width is roughly equivalent to a 10% valley. [1]

  5. Chromatography software - Wikipedia

    en.wikipedia.org/wiki/Chromatography_software

    Chromatography software is called also Chromatography Data System. [1] It is located in the data station of the modern liquid, gas or supercritical fluid chromatographic systems. This is a dedicated software connected to an hardware interface within the chromatographic system, which serves as a central hub for collecting, analyzing, and ...

  6. Fundamental resolution equation - Wikipedia

    en.wikipedia.org/wiki/Fundamental_Resolution...

    1) N can be increased by lengthening the column (least effective, as doubling the column will get a 2 1/2 or 1.44x increase in resolution). 2) Increasing k' also helps. This can be done by lowering the column temperature in G.C., or by choosing a weaker mobile phase in L.C. (moderately effective)

  7. Headspace gas chromatography for dissolved gas measurement

    en.wikipedia.org/wiki/Headspace_Gas...

    One of the most widely used methods for headspace analysis is described by the United States Environmental Protection Agency (USEPA). Originally developed by the R.S. Kerr USEPA Laboratory in Ada, Oklahoma as a "high quality, defendable, and documented way to measure" methane, ethane, and ethene, [7] [8] RSKSOP-175 is a standard operating procedure (SOP) and an unofficial method employed by ...

  8. Charged aerosol detector - Wikipedia

    en.wikipedia.org/wiki/Charged_Aerosol_Detector

    The charged aerosol detector (CAD) is a detector used in conjunction with high-performance liquid chromatography (HPLC) and ultra high-performance liquid chromatography (UHPLC) to measure the amount of chemicals in a sample by creating charged aerosol particles which are detected using an electrometer.

  9. Chromatography detector - Wikipedia

    en.wikipedia.org/wiki/Chromatography_detector

    A chromatography detector is a device that detects and quantifies separated compounds as they elute from the chromatographic column.These detectors are integral to various chromatographic techniques, such as gas chromatography, [1] liquid chromatography, and high-performance liquid chromatography, [2] and supercritical fluid chromatography [3] among others.