Search results
Results from the WOW.Com Content Network
In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t
Kirchhoff's voltage law: The directed sum of the electrical potential differences around a circuit must be zero. Ohm's Law : The voltage across a resistor is the product of its resistance and the current flowing through it, at constant temperature.
As with any wave equation, these equations lead to two types of solution: advanced potentials (which are related to the configuration of the sources at future points in time), and retarded potentials (which are related to the past configurations of the sources); the former are usually disregarded where the field is to analyzed from a causality ...
In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating voltages that are offset in time by one-third of the period. A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y').
The point where the lines cross is the quiescent operating point. Perhaps the easiest practical method is to calculate the (linear) network open circuit voltage and short circuit current and plot these on the transfer function of the non-linear device. The straight line joining these two point is the transfer function of the network.
In electrical engineering, susceptance (B) is the imaginary part of admittance (Y = G + jB), where the real part is conductance (G). The reciprocal of admittance is impedance (Z = R + jX), where the imaginary part is reactance (X) and the real part is resistance (R). In SI units, susceptance is measured in siemens (S).
Electrical conductors offer an intuitive example. If a and b are any two points within or at the surface of a given conductor, and given there is no flow of charge being exchanged between the two points, then the potential difference is zero between the two points. Thus, an equipotential would contain both points a and b as they have the same ...
Gabriel Kron (1901 – 1968) was a Hungarian American electrical engineer who promoted the use of methods of linear algebra, multilinear algebra, and differential geometry in the field. His method of system decomposition and solution called Diakoptics is still influential today. Though he published widely, his methods were slow to be assimilated.