enow.com Web Search

  1. Ads

    related to: high side current sense circuit

Search results

  1. Results from the WOW.Com Content Network
  2. Current sense amplifier - Wikipedia

    en.wikipedia.org/wiki/Current_sense_amplifier

    They utilize a "current-sense resistor" to convert the load current in the power rail to a small voltage, which is then amplified by the current-sense amplifiers. The currents in the power rail can be in the range of 1 A to 20 A, requiring the current-sense resistor to be a resistor typically in the range of 1 to 100 mΩ.

  3. Current sensing - Wikipedia

    en.wikipedia.org/wiki/Current_sensing

    In electrical engineering, current sensing is any one of several techniques used to measure electric current. The measurement of current ranges from picoamps to tens of thousands of amperes. The selection of a current sensing method depends on requirements such as magnitude, accuracy, bandwidth, robustness, cost, isolation or size. The current ...

  4. Current source - Wikipedia

    en.wikipedia.org/wiki/Current_source

    If the current through an ideal current source can be specified independently of any other variable in a circuit, it is called an independent current source. Conversely, if the current through an ideal current source is determined by some other voltage or current in a circuit, it is called a dependent or controlled current source. Symbols for ...

  5. Shunt (electrical) - Wikipedia

    en.wikipedia.org/wiki/Shunt_(electrical)

    If connected in series with the circuit it simply prevents reversed current, but if connected in parallel it can shunt the reversed supply, causing a fuse or other current limiting circuit to open. All semiconductor diodes have a threshold voltage – typically between 0.5 volt and 1 volt – that must be exceeded before significant current ...

  6. Current transformer - Wikipedia

    en.wikipedia.org/wiki/Current_transformer

    Instrument transformers isolate measurement or protection circuits from the high voltage of the primary system. A current transformer presents a negligible load to the primary circuit. [1] Current transformers are the current-sensing units of the power system and are used at generating stations, electrical substations, and in industrial and ...

  7. TL431 - Wikipedia

    en.wikipedia.org/wiki/TL431

    Closed-loop regulator circuits using the TL431 are always designed to operate in high transconductance mode, with I CA no less than 1 mA (point D on the current-voltage curve). [8] [7] [2] For better control loop stability, optimal I CA should be set at around 5 mA, although this may compromise overall efficiency. [30] [7]

  8. Four-terminal sensing - Wikipedia

    en.wikipedia.org/wiki/Four-terminal_sensing

    Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...

  9. Rogowski coil - Wikipedia

    en.wikipedia.org/wiki/Rogowski_coil

    The picture shows a Rogowski coil encircling a current-carrying cable. The output of the coil, v(t), is connected to a lossy integrator circuit to obtain a voltage V out (t) that is proportional to I(t). A Rogowski coil, named after Walter Rogowski, is an electrical device for measuring alternating current (AC) or high