enow.com Web Search

  1. Ads

    related to: 3 phase ac current sensor

Search results

  1. Results from the WOW.Com Content Network
  2. Current sensing - Wikipedia

    en.wikipedia.org/wiki/Current_sensing

    Fiber optic current sensor, using an interferometer to measure the phase change in the light produced by a magnetic field. Rogowski coil, electrical device for measuring alternating current (AC) or high speed current pulses. Giant Magnetoresistance(GMR): Magnetic field sensor suitable for AC & DC Current with higher accuracy than Hall Effect ...

  3. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3Ï• [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  4. Synchro - Wikipedia

    en.wikipedia.org/wiki/Synchro

    The excitation is often 208/240-V 3-phase mains power. Many synchros operate on 30 to 60 V AC also. Synchro transmitters are as described, but 50- and 60-Hz synchro receivers require rotary dampers to keep their shafts from oscillating when not loaded (as with dials) or lightly loaded in high-accuracy applications.

  5. Pulse Electronics' New Sidewinder AC Current Sensor Has a ...

    www.aol.com/2012/11/06/pulse-electronics-new...

    Pulse Electronics' New Sidewinder AC Current Sensor Has a Dynamic Range of 0.10-1000+ Amps For highly accurate power measurement in smart meters, industrial motor controls, and power line ...

  6. Rogowski coil - Wikipedia

    en.wikipedia.org/wiki/Rogowski_coil

    The picture shows a Rogowski coil encircling a current-carrying cable. The output of the coil, v(t), is connected to a lossy integrator circuit to obtain a voltage V out (t) that is proportional to I(t). A Rogowski coil, named after Walter Rogowski, is an electrical device for measuring alternating current (AC) or high

  7. Current clamp - Wikipedia

    en.wikipedia.org/wiki/Current_clamp

    This allows measurement of the current in a conductor without the need to make physical contact with it, or to disconnect it for insertion through the probe. Current clamps are typically used to read the magnitude of alternating current (AC) and, with additional instrumentation, the phase and waveform can also be measured. Some clamp meters can ...

  8. Current transformer - Wikipedia

    en.wikipedia.org/wiki/Current_transformer

    Current transformers used to sense ground fault (zero sequence) currents, such as in a three-phase installation, may have three primary conductors passed through the ring. Only the net unbalanced current produces a secondary current - this can be used to detect a fault from an energized conductor to ground.

  9. Alternating current - Wikipedia

    en.wikipedia.org/wiki/Alternating_current

    Three-phase electrical generation is very common. The simplest way is to use three separate coils in the generator stator, physically offset by an angle of 120° (one-third of a complete 360° phase) to each other. Three current waveforms are produced that are equal in magnitude and 120° out of phase to each other.

  1. Ads

    related to: 3 phase ac current sensor