A typical commercial air curtain enclosure. In North America, the more commonly-used term for an air door is "air curtain". The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) defines an air door as follows: "In its simplest application, an air curtain is a continuous broad stream of air circulated across a doorway of a conditioned space.
The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.
Air curtain may refer to: Air door, a fan-powered device used for separating two spaces from each other; Pneumatic barrier for containing oil spills; See also.
A further application of the pneumatic barrier is to decrease the salt-water exchange in navigation locks and prevent salt intrusion in rivers. . [1] Pneumatic barriers are also known as air curtains. The pneumatic barrier is a (non-patented) invention of the Dutch engineer Johan van Veen from around 1940 . [2]
A bubble curtain in Florida used to stop debris entering the marina. A bubble curtain is a system that produces bubbles in a deliberate arrangement in water. It is also called pneumatic barrier. The technique is based on bubbles of air (gas) being let out under the water surface, commonly on the bottom.
The above equation only takes into account the temperature differences and ignores two important parameters, being 1) solar radiative flux; and 2) infrared exchanges from the sky. The concept of T sol-air was thus introduced to enable these parameters to be included within an improved calculation. The following formula results:
Simply pumping air between a hull and the ground wasted a lot of energy in terms of leakage of air around the edges of the hull. Cockerell discovered that by means of generating a wall (curtain) of high-speed downward-directed air around the edges of a hull, that less air leaked out from the sides (due to the momentum of the high-speed air ...
A common feature in curtain wall technology, the rainscreen principle theorizes that equilibrium of air pressure between the outside and inside of the "rainscreen" prevents water penetration into the building. For example, the glass is captured between an inner and an outer gasket in a space called the glazing rebate.