enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Bode plot - Wikipedia

    en.wikipedia.org/wiki/Bode_plot

    Figure 1B: Low-pass filter (1st-order, one-pole) Bode magnitude plot (top) and Bode phase plot (bottom). The red data curve is approximated by the straight black line. In electrical engineering and control theory, a Bode plot is a graph of the frequency response of a system.

  3. Cutoff frequency - Wikipedia

    en.wikipedia.org/wiki/Cutoff_frequency

    The final step depends on the geometry of the waveguide. The easiest geometry to solve is the rectangular waveguide. In that case, the remainder of the Laplacian can be evaluated to its characteristic equation by considering solutions of the form ψ ( x , y , z , t ) = ψ 0 e i ( ω t − k z z − k x x − k y y ) . {\displaystyle \psi (x,y,z ...

  4. Talk:Bode plot - Wikipedia

    en.wikipedia.org/wiki/Talk:Bode_plot

    As I understand the bode plot, is the transfer function as it is on the imaginary axis (s=jw). The question then is, why are poles or zeros on the real axis of the transfer function create corners and phase changes on the imaginary axis, at the same value of frequency as the pole or zero?

  5. Phase margin - Wikipedia

    en.wikipedia.org/wiki/Phase_margin

    Bode plot illustrating phase margin. In electronic amplifiers, the phase margin (PM) is the difference between the phase lag φ (< 0) and -180°, for an amplifier's output signal (relative to its input) at zero dB gain - i.e. unity gain, or that the output signal has the same amplitude as the input.

  6. Step response - Wikipedia

    en.wikipedia.org/wiki/Step_response

    The procedure outlined in the Bode plot article is followed. Figure 5 is the Bode gain plot for the two-pole amplifier in the range of frequencies up to the second pole position. The assumption behind Figure 5 is that the frequency f 0 dB lies between the lowest pole at f 1 = 1/(2πτ 1) and the second pole at f 2 = 1/(2πτ 2). As indicated in ...

  7. BIBO stability - Wikipedia

    en.wikipedia.org/wiki/BIBO_stability

    For a rational and continuous-time system, the condition for stability is that the region of convergence (ROC) of the Laplace transform includes the imaginary axis.When the system is causal, the ROC is the open region to the right of a vertical line whose abscissa is the real part of the "largest pole", or the pole that has the greatest real part of any pole in the system.

  8. Bode's sensitivity integral - Wikipedia

    en.wikipedia.org/wiki/Bode's_sensitivity_integral

    Bode's sensitivity integral, discovered by Hendrik Wade Bode, is a formula that quantifies some of the limitations in feedback control of linear parameter invariant systems. Let L be the loop transfer function and S be the sensitivity function .

  9. Dielectric spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Dielectric_spectroscopy

    The real and imaginary parts of permittivity are shown, and various processes are depicted: ionic and dipolar relaxation, and atomic and electronic resonances at higher energies. [ 1 ] Dielectric spectroscopy (which falls in a subcategory of the impedance spectroscopy ) measures the dielectric properties of a medium as a function of frequency .