DOAS Diagram. Moisture Removal Efficiency (MRE) is a measure of the energy efficiency of any dehumidification process. Moisture removal efficiency is the water vapor removed from air at a defined inlet air temperature and humidity, divided by the total energy consumed by the dehumidification equipment during the same time period, including all fan and pump energy needed to move air and fluids ...
A typical "portable" dehumidifier can be moved about on built-in casters. A dehumidifier is an air conditioning device which reduces and maintains the level of humidity in the air. [1] This is done usually for health or thermal comfort reasons or to eliminate musty odor and to prevent the growth of mildew by extracting water from the air. It ...
Xchanger Inc, webpage Calculator for humidity, dew point, mass flows & heat flux for variable pressure systems with compressors, blowers, vacuum pumps and heat exchangers. Corwin's Calculators Calculator for humidity, dew point. How to read and use a psychrometric chart; Free Online Interactive Psychrometric Chart
Increasing the barometric pressure raises the dew point. [11] This means that, if the pressure increases, the mass of water vapor per volume unit of air must be reduced in order to maintain the same dew point. For example, consider New York City (33 ft or 10 m elevation) and Denver (5,280 ft or 1,610 m elevation [12]). Because Denver is at a ...
The wet-bulb temperature is the lowest temperature that may be achieved by evaporative cooling of a water-wetted, ventilated surface.. By contrast, the dew point is the temperature to which the ambient air must be cooled to reach 100% relative humidity assuming there is no further evaporation into the air; it is the temperature where condensation (dew) and clouds would form.
Adjusting is the final setting of balancing devices such as dampers and valves, adjusting fan speeds and pump impeller sizes, in addition to automatic control devices such as thermostats and pressure controllers to achieve maximum specified system performance and efficiency during normal operation.
It is defined as the pressure exerted by a column of water of 1 inch in height at defined conditions. At a temperature of 4 °C (39.2 °F) pure water has its highest density (1000 kg/m 3 ). At that temperature and assuming the standard acceleration of gravity , 1 inAq is approximately 249.082 pascals (0.0361263 psi ).
Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.