Average values for FEV1 in healthy people depend mainly on sex and age, according to the diagram. Values of between 80% and 120% of the average value are considered normal. [14] Predicted normal values for FEV1 can be calculated and depend on age, sex, height, mass and ethnicity as well as the research study that they are based on.
In obstructive lung disease, the FEV1 is reduced due to an obstruction of air escaping from the lungs. Thus, the FEV1/FVC ratio will be reduced. [4] More specifically, according to the National Institute for Clinical Excellence, the diagnosis of COPD is made when the FEV 1 /FVC ratio is less than 0.7 or [8] the FEV 1 is less than 75% of predicted; [9] however, other authoritative bodies have ...
The difference between the highest values of two FVCs need to be within 5% or 150 mL. When the FVC is less than 1.0 L, the difference between the highest two values must be within 100 mL. Lastly, the difference between the two highest values of FEV1 should also be within 150 mL. The highest FVC and FEV1 may be used from each different test.
Online calculators are available that can compute predicted lung volumes, and other spirometric parameters based on a patient's age, height, weight, and ethnic origin for many reference sources. British rower and three-time Olympic gold medalist Pete Reed is reported to hold the largest recorded lung capacity of 11.68 litres; [ 16 ] [ 17 ] [ 18 ...
For this reason, tables or charts are used to determine the normal value for a particular individual. More recently, medical calculators have been developed to calculate predicted values for peak expiratory flow. There are a number of non-equivalent scales used in the interpretation of peak expiratory flow.
Output of a spirometer. Vital capacity (VC) is the maximum amount of air a person can expel from the lungs after a maximum inhalation.It is equal to the sum of inspiratory reserve volume, tidal volume, and expiratory reserve volume.
There is no universally recognized reference value range for DLCO as of 2017, [10] but values in the 80%-120% of predicted range based on instrument manufacturer standards are generally considered normal. [11] A D LCO of less than 60% predicted portends a poor prognosis for lung cancer resection.