  2. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    In Europe, the standard temperature is most commonly defined as 0 °C, but not always. In the United States, the EPA defines standard conditions for volume and volumetric flow as a temperature of 293 K (68 °F) and a pressure of 101.3 kilopascals (29.92 in. Hg), [1] although various industry users may use definitions from 60 °F to 78 °F.

  3. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  4. Useful conversions and formulas for air dispersion modeling

    en.wikipedia.org/wiki/Useful_conversions_and...

    A normal cubic meter (Nm 3) is the metric expression of gas volume at standard conditions and it is usually (but not always) defined as being measured at 0 °C and 1 atmosphere of pressure. A standard cubic foot (scf) is the USA expression of gas volume at standard conditions and it is often (but not always) defined as being measured at 60 °F ...

  5. Standard cubic foot - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_foot

    An actual volume can be converted to a standard volume using the following equation: [6] [7] V s = V a × F p × F t × (F pv) 2. Where, V s: standard volume V a: actual volume (sometimes shown as V r for registered volume) F p: pressure factor (sometimes shown as P m for pressure multiplier)

  6. Volumetric flow rate - Wikipedia

    en.wikipedia.org/wiki/Volumetric_flow_rate

    The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .

  7. Standard litre per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_litre_per_minute

    Until 1982, STP was defined as a temperature of 273.15 K (0 °C, 32 °F) and an absolute pressure of 101.325 kPa (1 atm). Since 1982, STP is defined as a temperature of 273.15 K (0 °C, 32 °F) and an absolute pressure of 100 kPa (1 bar). Conversions between each volume flow metric are calculated using the following formulas: Prior to 1982,

  8. Standard temperature and pressure - Wikipedia

    en.wikipedia.org/wiki/Standard_temperature_and...

    This standard is also called normal temperature and pressure (abbreviated as NTP). However, a common temperature and pressure in use by NIST for thermodynamic experiments is 298.15 K (25 °C, 77 °F) and 1 bar (14.5038 psi, 100 kPa).

  9. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    The actual amount of air changed in a well mixed ventilation scenario will be 63.2% after 1 hour and 1 ACH. [3] In order to achieve equilibrium pressure, the amount of return air (air leaving the space) and the amount of supply air (air entering the space) must be the same.