An axial belt-drive exhaust fan serving an underground car park. This exhaust fan's operation is interlocked with the concentration of contaminants emitted by internal combustion engines. Mechanical ventilation of buildings and structures can be achieved by the use of the following techniques: Whole-house ventilation; Mixing ventilation
Thermoelectric dehumidifiers use a Peltier heat pump to cool a surface and condense water vapor from the air. The design is simpler and has the benefit of being quieter compared to a dehumidifier with a mechanical compressor. However, because of its relatively poor Coefficient of Performance, this design is mainly used for small dehumidifiers ...
DOAS Diagram. Moisture Removal Efficiency (MRE) is a measure of the energy efficiency of any dehumidification process. Moisture removal efficiency is the water vapor removed from air at a defined inlet air temperature and humidity, divided by the total energy consumed by the dehumidification equipment during the same time period, including all fan and pump energy needed to move air and fluids ...
HVAC ventilation exhaust for a 12-story building An axial belt-drive exhaust fan serving an underground car park. This exhaust fan's operation is interlocked with the concentration of contaminants emitted by internal combustion engines. Mechanical, or forced, ventilation is provided by an air handler (AHU) and used to control indoor air quality.
Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...
Heating, cooling, ventilation and exhaustion are all key areas to consider in the mechanical planning of a building. [4] In special cases, water cooling/heating, humidity control or air filtration [5] may also be incorporated. For example, Google's data centres make extensive use of heat exchangers to cool their servers. [6]
A waterproof weight is used to sink the towel in the center of the bowl. There is no need for a fan, because the water spreads through the towel by capillary action and the towel surface area is large enough to provide for rapid evaporation. The stainless steel bowl is much easier to clean than typical humidifier water tanks.
Small air handlers, for local use, are called terminal units, and may only include an air filter, coil, and blower; these simple terminal units are called blower coils or fan coil units. A larger air handler that conditions 100% outside air, and no recirculated air, is known as a makeup air unit ( MAU ) or fresh air handling unit ( FAHU ).