enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Reinforced concrete column - Wikipedia

    en.wikipedia.org/wiki/Reinforced_Concrete_Column

    The ACI codebook puts an upward limit on the spacing between ties. ACI Code 7.10.5: Vertical spacing of ties shall not exceed 16 longitudinal bar diameters, 48 tie bar or wire diameters, or least dimension of the compression member. If the ties are spaced too far apart, the column will experience shearfailure and barrel in between the ties. [4]

  3. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.

  4. Waffle slab - Wikipedia

    en.wikipedia.org/wiki/Waffle_slab

    The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of the span between columns. Its height should be the same as the ribs. [3] Diagram showing waffle slab rib and Beam Heights rule of thumb formulas.

  5. Intercolumniation - Wikipedia

    en.wikipedia.org/wiki/Intercolumniation

    In architecture, intercolumniation is the proportional spacing between columns in a colonnade, often expressed as a multiple of the column diameter as measured at the bottom of the shaft. [1] In Classical , Renaissance , and Baroque architecture , intercolumniation was determined by a system described by the first-century BC Roman architect ...

  6. Column - Wikipedia

    en.wikipedia.org/wiki/Column

    Modern columns may be constructed out of steel, poured or precast concrete, or brick, left bare or clad in an architectural covering, or veneer. Used to support an arch, an impost, or pier, is the topmost member of a column. The bottom-most part of the arch, called the springing, rests on the impost.

  7. Washington Square (Bellevue, Washington) - Wikipedia

    en.wikipedia.org/wiki/Washington_Square...

    Washington Square comprises two towers constructed using steel-reinforced concrete, classified as "Type I Construction". Each tower encompasses 24 stories and is designed with slab thicknesses and column spacing capable of withstanding the seismic and wind loading common in the Northwest region.

  8. Double tee - Wikipedia

    en.wikipedia.org/wiki/Double_tee

    The first building with all pre-stressed concrete columns, beams, and double tees was a two-story office building in Winter Haven, Florida, designed and built in 1961 by Gene Leedy. Leedy experimented when building his architectural office by using structural elements of prestressed concrete and designing the new "double-tee" structural elements.

  9. Shallow foundation - Wikipedia

    en.wikipedia.org/wiki/Shallow_foundation

    A strap footing connects individual columns with the use of a strap beam. The general purpose of a strap footing is alike to those of a combined footing, where the spacing is possibly limited and/or the columns are adjacent to the property lines. Mat foundation with its concrete undergoing curing.