Venous return (VR) is the flow of blood back to the heart. Under steady-state conditions, venous return must equal cardiac output (Q), when averaged over time because the cardiovascular system is essentially a closed loop. Otherwise, blood would accumulate in either the systemic or pulmonary circulations.
Cerebral blood flow (CBF) is the blood supply to the brain in a given period of time. [8] In an adult, CBF is typically 750 millilitres per minute or 15.8 ± 5.7% of the cardiac output . [ 9 ] This equates to an average perfusion of 50 to 54 millilitres of blood per 100 grams of brain tissue per minute.
The Fick principle states that blood flow to an organ can be calculated using a marker substance if the following information is known: Amount of marker substance taken up by the organ per unit time; Concentration of marker substance in arterial blood supplying the organ; Concentration of marker substance in venous blood leaving the organ
For this reason, the blood flow velocity is the fastest in the middle of the vessel and slowest at the vessel wall. In most cases, the mean velocity is used. [18] There are many ways to measure blood flow velocity, like videocapillary microscoping with frame-to-frame analysis, or laser Doppler anemometry. [19]
In whole blood (g/cm 3) In plasma or serum (g/cm 3) Water: Solvent 0.81-0.86 0.93-0.95 Acetoacetate: Produced in liver 8-40 × 10 −7: 4-43 × 10 −7: Acetone: product of bodyfat breakdown 3-20 × 10 −6: Acetylcholine: Neurotransmitter of the parasympathetic nervous system: 6.6-8.2 × 10 −8: Adenosine triphosphate: Energy storage total 3. ...
Vascular resistance occurs when the vessels away from the heart oppose the flow of blood. Resistance is an accumulation of three different factors: blood viscosity, blood vessel length and vessel radius. [30] Blood viscosity is the thickness of the blood and its resistance to flow as a result of the different components of the blood.
Modalities applied to measurement of ejection fraction is an emerging field of medical mathematics and subsequent computational applications. The first common measurement method is echocardiography, [7] [8] although cardiac magnetic resonance imaging (MRI), [8] [9] cardiac computed tomography, [8] [9] ventriculography and nuclear medicine (gated SPECT and radionuclide angiography) [8] [10 ...
It is a dimensionless expression of the pulsatile flow frequency in relation to viscous effects. It is named after John R. Womersley (1907–1958) for his work with blood flow in arteries. [1] The Womersley number is important in keeping dynamic similarity when scaling an experiment. An example of this is scaling up the vascular system for ...