Plenum cable / ˈ p l ɛ n əm / is electrical cable that is laid in the plenum spaces of buildings. In the United States , plastics used in the construction of plenum cable are regulated under the National Fire Protection Association standard NFPA 90A: Standard for the Installation of Air Conditioning and Ventilating Systems.
Coaxial cables are often joined with power cables for CCTV use, meaning that only one cable has to be run to provide a both video and power connections. [10] Twisted pair cables such as Ethernet cables are sometimes combined with fiber-optic cables. A common configuration is a four-pair Category 5 cable with two strands of multimode fiber optic ...
Cable types, connector types and cabling topologies are defined by ANSI/TIA-568. Category 5 cable is nearly always terminated with 8P8C modular connectors (often referred to incorrectly as RJ45 connectors [14] [15] [16]). The cable is terminated in either the T568A scheme or the T568B scheme. The two schemes work equally well and may be mixed ...
Structured cabling design and installation is governed by a set of standards that specify wiring data centers, offices, and apartment buildings for data or voice communications using various kinds of cable, most commonly Category 5e (Cat 5e), Category 6 (Cat 6), and fiber-optic cabling and modular connectors.
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
Starting with the first binder group in the center, the technician counts the cable's groups in a spiral direction depending on the location of the central office or switch. If looking at the cable's core and the switch is in that direction, the groups are counted counter-clockwise. If the cable is the field side, the count is clockwise. There ...
Optical Carrier classifications are based on the abbreviation OC followed by a number specifying a multiple of 51.84 Mbit/s: n × 51.84 Mbit/s => OC-n. For example, an OC-3 transmission medium has 3 times the transmission capacity of OC-1.
Generally, layers are named by their specifications: [8] 10, 100, 1000, 10G, ... – the nominal, usable speed at the top of the physical layer (no suffix = megabit/s, G = gigabit/s), excluding line codes but including other physical layer overhead (preamble, SFD, IPG); some WAN PHYs (W) run at slightly reduced bitrates for compatibility reasons; encoded PHY sublayers usually run at higher ...