Search results
Results from the WOW.Com Content Network
A RAID 0 array of n drives provides data read and write transfer rates up to n times as high as the individual drive rates, but with no data redundancy. As a result, RAID 0 is primarily used in applications that require high performance and are able to tolerate lower reliability, such as in scientific computing [5] or gaming.
RAID 01, also called RAID 0+1, is a RAID level using a mirror of stripes, achieving both replication and sharing of data between disks. [3] The usable capacity of a RAID 01 array is the same as in a RAID 1 array made of the same drives, in which one half of the drives is used to mirror the other half.
RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.
RAID 5E, RAID 5EE, and RAID 6E (with the added E standing for Enhanced) generally refer to variants of RAID 5 or 6 with an integrated hot-spare drive, where the spare drive is an active part of the block rotation scheme. This spreads I/O across all drives, including the spare, thus reducing the load on each drive, increasing performance.
The RAID 0 volume in Matrix RAID provides fast access to large files where data loss is not a critical issue but speed is; examples include video editing, swap files, and files that are backed up. Intel Matrix RAID, Intel Rapid RAID, and Intel Smart Response Technology are together described as Intel Rapid Storage Technology. [9]
RAID In some RAID configurations, such as RAID 0, failure of a single member drive of the RAID array causes all stored data to be lost. In other RAID configurations, such as a RAID 5 that contains distributed parity and provides redundancy, if one member drive fails the data can be restored using the other drives in the array. LVM2
RAID stands for redundant array of independent disks (or, formerly, redundant array of inexpensive disks). RAID levels may refer to: Standard RAID levels , all the RAID configurations defined in the Common RAID Disk Drive Format standard, which is maintained by the Storage Networking Industry Association
If RAID 0 were used, then disk 0 and disk 2 would be truncated to 28 blocks, the size of the smallest disk in the array (disk 1) for a total size of 84 blocks. [citation needed] What makes a SPAN or BIG different from RAID configurations is the possibility for the selection of drives.