Search results
Results from the WOW.Com Content Network
This is the method used in the original discovery of X-ray diffraction. Laue scattering provides much structural information with only a short exposure to the X-ray beam, and is therefore used in structural studies of very rapid events (time resolved crystallography). However, it is not as well-suited as monochromatic scattering for determining ...
An X-ray diffraction pattern of a crystallized enzyme. The pattern of spots (reflections) and the relative strength of each spot (intensities) can be used to determine the structure of the enzyme. The relative intensities of the reflections provides information to determine the arrangement of molecules within the crystal in atomic detail.
X-ray optics is the branch of optics dealing with X-rays, rather than visible light.It deals with focusing and other ways of manipulating the X-ray beams for research techniques such as X-ray diffraction, X-ray crystallography, X-ray fluorescence, small-angle X-ray scattering, X-ray microscopy, X-ray phase-contrast imaging, and X-ray astronomy.
Rigaku manufactures and supplies scientific instrumentation to academia, industry and trade. These include X-ray diffractometers, single crystal diffractometers, X-ray Imagers, X-ray fluorescence spectrometers (both Energy Dispersive and Wavelength Dispersive varieties), thermal analysis equipment, Handheld Raman and LIBS analyzers and X-ray and EUV optics, X-ray sources and X-ray detectors.
There are several types of X-ray diffractometer, depending on the research field (material sciences, powder diffraction, life sciences, structural biology, etc.) and the experimental environment, if it is a laboratory with its home X-ray source or a Synchrotron. In laboratory, diffractometers are usually an "all in one" equipment, including the ...
X-ray filters are also used for X-ray diffraction, in determinations of the interatomic spaces of crystalline solids. These lattice spacings can be determined using Bragg diffraction, but this technique requires scans to be done with approximately monochromatic X-ray beams. Thus, filter set ups like the copper nickel system described above are ...
The development of dark-field X-ray microscopy has been driven by the need for non-destructive imaging of bulk crystalline samples at high resolution, and it continues to be an active area of research today. However, dark-field microscopy, [3] [4] dark-field scanning transmission X-ray microscopy, [5] and soft dark-field X-ray microscopy [6 ...
In X-ray diffraction, the Rachinger correction is a method for accounting for the effect of an undesired K-alpha 2 peak in the energy spectrum. Ideally, diffraction measurements are made with X-rays of a single wavelength. Practically, the x-rays for a measurement are usually generated in an X-ray tube from a metal's K-alpha line. This ...