Search results
Results from the WOW.Com Content Network
A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...
Soft (or ductile) copper tubing can be bent easily to travel around obstacles in the path of the tubing. While the work hardening of the drawing process used to size the tubing makes the copper hard or rigid, it is carefully annealed to make it soft again; it is, therefore, more expensive to produce than non-annealed, rigid copper tubing.
A reversing valve removed from an HVAC heat pump for replacement. A reversing valve is a type of valve and is a component in a heat pump, that changes the direction of refrigerant flow. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a residence or facility to ...
An isolation valve is a valve in a fluid handling system that stops the flow of process media to a given location, usually for maintenance or safety purposes. [1] They can also be used to provide flow logic (selecting one flow path versus another), and to connect external equipment to a system. [2]
For Type I systems the main requirement is to remove 80% of the refrigerant if the appliance's compressor is not running and 90% if running and evacuate to a 4 inch Hg vacuum. For Type II or Type III applications, the appliance must be evacuated to the following levels for device manufactured after November 15, 1993 in order to recover the ...
The EPA defines refrigerant reclamation as "Reclaim refrigerant means to reprocess refrigerant to at least the purity specified in appendix A to 40 CFR part 82, subpart F (based on AHRI Standard 700–1993, Specifications for Fluorocarbon and Other Refrigerants) and to verify this purity using the analytical methodology prescribed in appendix A ...
The thermostat controls the fan speed and/or the flow of water or refrigerant to the heat exchanger using a control valve. Due to their simplicity, flexibility, and easy maintenance, fan coil units can be more economical to install than ducted 100% fresh air systems (VAV) or central heating systems with air handling units or chilled beams. FCUs ...
A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...