enow.com Web Search

  1. Ads

    related to: free heat pump sizing calculator

Search results

  1. Results from the WOW.Com Content Network
  2. Heating seasonal performance factor - Wikipedia

    en.wikipedia.org/wiki/Heating_seasonal...

    A well designed ground source heat pump installation should achieve an SPF of 3.5, or over 5 if linked to a solar-assisted thermal bank. [6] Example: For a heat pump delivering 120,000,000 BTU during the season, when consuming 15,000 kWh, the HSPF can be calculated as : HSPF = 120000000 (BTU) / (1000) / 15000 (kWh) HSPF = 8

  3. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The heat pump itself can be improved by increasing the size of the internal heat exchangers, which in turn increases the efficiency (and the cost) relative to the power of the compressor, and also by reducing the system's internal temperature gap over the compressor. Obviously, this latter measure makes some heat pumps unsuitable to produce ...

  4. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load. These include the global coordinates of the site and the size of the structure. [1] [5]

  5. Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Seasonal_energy_efficiency...

    In the United States, the efficiency of air conditioners is often rated by the seasonal energy efficiency ratio (SEER) which is defined by the Air Conditioning, Heating, and Refrigeration Institute, a trade association, in its 2008 standard AHRI 210/240, Performance Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment. [1]

  6. Absorption heat pump - Wikipedia

    en.wikipedia.org/wiki/Absorption_heat_pump

    The coefficient of performance of the first type absorption heat pump is greater than 1, generally 1.5 to 2.5. [4] The heat pump is composed of the main components such as generators, condenser, evaporator, absorber and heat exchanger, as well as the suction device, shielding pump (solution pump and refrigerant pump), and other auxiliary parts.

  7. Ground source heat pump - Wikipedia

    en.wikipedia.org/wiki/Ground_source_heat_pump

    These heat pumps are also preferred for pool heating. Heat pumps typically only heat water to about 55 °C (131 °F) efficiently, whereas boilers typically operate at 65–95 °C (149–203 °F) [citation needed]. The size of radiators designed for the higher temperatures achieved by boilers may be too small for use with heat pumps, requiring ...

  1. Ads

    related to: free heat pump sizing calculator