An MRI pulse sequence in magnetic resonance imaging (MRI) is a particular setting of pulse sequences and pulsed field gradients, resulting in a particular image appearance. [ 1 ] A multiparametric MRI is a combination of two or more sequences, and/or including other specialized MRI configurations such as spectroscopy .
The thin bar denotes a 90° pulse, while the thick bar denotes a 180° pulse. INEPT is a common building block of NMR experiments to improve 15 N signal. [1] In Fourier transform NMR spectroscopy and imaging, a pulse sequence describes a series of radio frequency pulses applied to the sample, such that the free induction decay is related
Standard foundation and comparison for other sequences Proton density weighted: PD: Long TR (to reduce T1) and short TE (to minimize T2). [4] Joint disease and injury. [5] High signal from meniscus tears. [6] (pictured) Gradient echo (GRE) Steady-state free precession: SSFP: Maintenance of a steady, residual transverse magnetisation over ...
Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to form pictures of the anatomy and the physiological processes inside the body. MRI scanners use strong magnetic fields , magnetic field gradients, and radio waves to generate images of the organs in the body.
Fluid-attenuated inversion recovery (FLAIR) [2] is an inversion-recovery pulse sequence used to nullify the signal from fluids. For example, it can be used in brain imaging to suppress cerebrospinal fluid so as to bring out periventricular hyperintense lesions, such as multiple sclerosis plaques.
Modern 3 Tesla clinical MRI scanner.. Magnetic resonance imaging (MRI) is a medical imaging technique mostly used in radiology and nuclear medicine in order to investigate the anatomy and physiology of the body, and to detect pathologies including tumors, inflammation, neurological conditions such as stroke, disorders of muscles and joints, and abnormalities in the heart and blood vessels ...
Susceptibility weighted imaging (SWI), originally called BOLD venographic imaging, is an MRI sequence that is exquisitely sensitive to venous blood, hemorrhage and iron storage. SWI uses a fully flow compensated, long echo, gradient recalled echo (GRE) pulse sequence to acquire images.
BIR-1 pulse sequence for 90-degree and 45-degree flip-angles. An important BIR pulse is known as the BIR-1. In this sequence, B effective is applied initially along the +x-axis in the rotating frame, and then adiabatically swept from the +x-axis to the +z-axis.