Search results
Results from the WOW.Com Content Network
A fire barrier wall, or a fire partition, is a fire-rated wall assembly that are not structurally self-sufficient. [ 2 ] Fire barrier walls are typically continuous from an exterior wall to an exterior wall, or from a floor below to a floor or roof above, or from one fire barrier wall to another fire barrier wall, having a fire resistance ...
The primary North American document that deals with outdoor high-voltage transformer fire barriers is NFPA 850. [1] NFPA 850 outlines that outdoor oil-insulated transformers should be separated from adjacent structures and from each other by firewalls, spatial separation, or other approved means for the purpose of limiting the damage and potential spread of fire from a transformer failure.
A fire door is a door with a fire-resistance rating (sometimes referred to as a fire protection rating for closures) used as part of a passive fire protection system to reduce the spread of fire and smoke between separate compartments of a structure and to enable safe egress from a building or structure or ship.
In order to achieve these objectives, all building enclosure systems must include a solid structure, a drainage plane, an air barrier, a thermal barrier, and may include a vapor barrier. Moisture control (e.g. damp proofing ) is essential in all climates, but cold climates and hot-humid climates are especially demanding.
A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke.
A curtain wall is an exterior covering of a building in which the outer walls are non-structural, instead serving to protect the interior of the building from the elements. Because the curtain wall façade carries no structural load beyond its own dead load weight, it can be made of lightweight materials.
A firewall installed between substation transformers. In fire safety, compartmentation in structures, such as land-based buildings, traffic tunnels, ships, aerospace vehicles, or submarines, is an objective of passive fire protection, in which a structure is divided into fire compartments, which may contain single or multiple rooms, for the purpose of limiting the spread of fire, smoke and ...
The function of a vapor barrier is to retard the migration of water vapor. A vapor barrier is not typically intended to retard the migration of air. This is the function of air barriers. [8] Air is mixed with water vapor. When air moves from location to location due to an air pressure difference, the vapor moves with it.