enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Closed-loop controller - Wikipedia

    en.wikipedia.org/wiki/Closed-loop_controller

    A closed loop controller therefore has a feedback loop which ensures the controller exerts a control action to give a process output the same as the "reference input" or "set point". For this reason, closed loop controllers are also called feedback controllers. [3] The definition of a closed loop control system according to the British ...

  3. Control loop - Wikipedia

    en.wikipedia.org/wiki/Control_loop

    A control loop is the fundamental building block of control systems in general and industrial control systems in particular. It consists of the process sensor, the controller function, and the final control element (FCE) which controls the process necessary to automatically adjust the value of a measured process variable (PV) to equal the value of a desired set-point (SP).

  4. Closed-loop transfer function - Wikipedia

    en.wikipedia.org/wiki/Closed-loop_transfer_function

    The closed-loop transfer function is measured at the output. The output signal can be calculated from the closed-loop transfer function and the input signal. Signals may be waveforms, images, or other types of data streams. An example of a closed-loop block diagram, from which a transfer function may be computed, is shown below:

  5. Sensitivity (control systems) - Wikipedia

    en.wikipedia.org/wiki/Sensitivity_(control_systems)

    Block diagram of a control system with disturbance. The sensitivity function also describes the transfer function from external disturbance to process output. In fact, assuming an additive disturbance n after the output of the plant, the transfer functions of the closed loop system are given by

  6. Current sensing - Wikipedia

    en.wikipedia.org/wiki/Current_sensing

    Fluxgate sensors or saturable inductor current sensors work on the same measurement principle as Hall-effect-based current sensors: the magnetic field created by the primary current to be measured is detected by a specific sensing element. The design of the saturable inductor current sensor is similar to that of a closed-loop Hall-effect ...

  7. Current loop - Wikipedia

    en.wikipedia.org/wiki/Current_loop

    A major application of current loops is the industry de facto standard 4–20 mA current loop for process control applications, where they are extensively used to carry signals from process instrumentation to proportional–integral–derivative (PID) controllers, supervisory control and data acquisition (SCADA) systems, and programmable logic ...

  8. Feed forward (control) - Wikipedia

    en.wikipedia.org/wiki/Feed_forward_(control)

    In systems theory, an open system is a feed forward system that does not have any feedback loop to control its output. In contrast, a closed system uses on a feedback loop to control the operation of the system. In an open system, the output of the system is not fed back into the input to the system for control or operation.

  9. Control theory - Wikipedia

    en.wikipedia.org/wiki/Control_theory

    A closed loop controller therefore has a feedback loop which ensures the controller exerts a control action to give a process output the same as the "reference input" or "set point". For this reason, closed loop controllers are also called feedback controllers. [11] The definition of a closed loop control system according to the British ...