enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Reinforced concrete column - Wikipedia

    en.wikipedia.org/wiki/Reinforced_Concrete_Column

    ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in. Section 10.9.3 adds an additional lower limit to the amount of spiral reinforcement via the volumetric spiral reinforcement ratio ρ s.

  3. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.

  4. Double tee - Wikipedia

    en.wikipedia.org/wiki/Double_tee

    Diagram of double tee beam. A double tee or double-T beam is a load-bearing structure that resembles two T-beams connected to each other side by side. The strong bond of the flange (horizontal section) and the two webs (vertical members, also known as stems) creates a structure that is capable of withstanding high loads while having a long span.

  5. T-beam - Wikipedia

    en.wikipedia.org/wiki/T-beam

    Unlike an I-beam, a T-beam lacks a bottom flange, which carries savings in terms of materials, but at the loss of resistance to tensile forces. [5] T- beam designs come in many sizes, lengths and widths to suit where they are to be used (eg highway bridge, underground parking garage) and how they have to resist the tension, compression and shear stresses associated with beam bending in their ...

  6. Reinforced concrete - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete

    The plate assemblies are fabricated off site, and welded together on-site to form steel walls connected by stringers. The walls become the form into which concrete is poured. Steel plate construction speeds reinforced concrete construction by cutting out the time-consuming on-site manual steps of tying rebar and building forms.

  7. Waffle slab - Wikipedia

    en.wikipedia.org/wiki/Waffle_slab

    The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of the span between columns. Its height should be the same as the ribs. [3] Diagram showing waffle slab rib and Beam Heights rule of thumb formulas.

  8. Formwork - Wikipedia

    en.wikipedia.org/wiki/Formwork

    Formwork tables in use at a building site with more complicated structural features. Crane fork or elevator handled: By this approach the tables are limited in size and weight. Typical widths are between 6 and 10 feet (1.8 and 3.0 m), typical lengths are between 12 and 20 feet (3.7 and 6.1 m), though table sizes may vary in size and form.

  9. Grade beam - Wikipedia

    en.wikipedia.org/wiki/Grade_beam

    Grade beam. A grade beam or grade beam footing is a component of a building's foundation. It consists of a reinforced concrete beam that transmits the load from a bearing wall into spaced foundations such as pile caps or caissons. [1] It is used in conditions where the surface soil's load-bearing capacity is less than the anticipated design loads.