Search results
Results from the WOW.Com Content Network
The last half of the T wave is referred to as the relative refractory period or vulnerable period. The T wave contains more information than the QT interval. The T wave can be described by its symmetry, skewness, slope of ascending and descending limbs, amplitude and subintervals like the T peak –T end interval. [1]
Electrocardiography is the process of producing an electrocardiogram (ECG or EKG [a]), a recording of the heart's electrical activity through repeated cardiac cycles. [4] It is an electrogram of the heart which is a graph of voltage versus time of the electrical activity of the heart [5] using electrodes placed on the skin.
An ST elevation is considered significant if the vertical distance inside the ECG trace and the baseline at a point 0.04 seconds after the J-point is at least 0.1 mV (usually representing 1 mm or 1 small square) in a limb lead or 0.2 mV (2 mm or 2 small squares) in a precordial lead. [2] The baseline is either the PR interval or the TP interval ...
Schematic representation of normal ECG. In electrocardiography, the ST segment connects the QRS complex and the T wave and has a duration of 0.005 to 0.150 sec (5 to 150 ms). It starts at the J point (junction between the QRS complex and ST segment) and ends at the beginning of the T wave.
The last event of the cycle is the repolarization of the ventricles. It is the restoring of the resting state. It is the restoring of the resting state. In the ECG, repolarization includes the J point, ST segment, and T and U waves. [ 9 ]
During "ejection" stage, the (red-line) tracing of "ventricular volume" falls to its least amount (see ejection fraction) as the ventricles pump blood to the pulmonary arteries and to the aorta. The cardiac cycle involves four major stages of activity: 1) "isovolumic relaxation", 2) inflow, 3) "isovolumic contraction", 4) "ejection".
Schematic representation of a normal sinus rhythm ECG wave. Diagram showing how the polarity of the QRS complex in leads I, II, and III can be used to estimate the heart's electrical axis in the frontal plane. The QRS complex is the combination of three of the graphical deflections seen on a typical electrocardiogram (ECG or EKG). It is usually ...
QT interval in an ECG complex can be measured manually by different methods, such as the threshold method, in which the end of the T wave is determined by the point at which the component of the T wave merges with the isoelectric baseline, or the tangent method, in which the end of the T wave is determined by the intersection of a tangent line ...