  1. Results from the WOW.Com Content Network
  2. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    Pressure independent control valves are used to limit the flow to the fan coil terminal and air handling unit. This flow is not affected by changes in inlet pressure. A diaphragm within the valve keeps the outlet pressure constant, and this delivers a constant flow to the terminal. The added advantage of pressure independent control valves is ...

  3. Freeze stat - Wikipedia

    en.wikipedia.org/wiki/Freeze_stat

    Air coil freeze stat. A freeze stat is a temperature sensing device for HVAC that monitors a heat exchanger to prevent its coils from freezing.Freeze stats can be used on both refrigerant-to-air, and refrigerant-to-liquid type heat exchangers and serve different purposes with similar goals for each.

  4. OpenTherm - Wikipedia

    en.wikipedia.org/wiki/OpenTherm

    OpenTherm (OT) is a standard communications protocol used in central heating systems for the communication between central heating appliances and a thermostatic controllers. [1] As a standard, OpenTherm is independent of any single manufacturer. A controller from one manufacturer can in principle be used to control a boiler from another ...

  5. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...

  6. Building automation - Wikipedia

    en.wikipedia.org/wiki/Building_automation

    Building automation (BAS), also known as building management system (BMS) or building energy management system (BEMS), is the automatic centralized control of a building's HVAC (heating, ventilation and air conditioning), electrical, lighting, shading, access control, security systems, and other interrelated systems.

  7. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.