Search results
Results from the WOW.Com Content Network
In United States Pharmacopeia (USP) General Chapter <711> Dissolution, there are four dissolution apparatuses standardized and specified. [6] They are: USP Dissolution Apparatus 1 – Basket (37 °C ± 0.5 °C ) USP Dissolution Apparatus 2 – Paddle (37 °C ± 0.5 °C) USP Dissolution Apparatus 3 – Reciprocating Cylinder (37 °C ± 0.5 °C)
In pharmaceutics, sink condition is a term mostly related to the dissolution testing procedure.. It means using a sheer volume of solvent, usually about 5 to 10 times greater than the volume present in the saturated solution of the targeted chemical (often the API, and sometimes the excipients) contained in the dosage form being tested.
As the stomach has an aqueous environment, it is the first place where the pill can dissolve. The rate of dissolution is a key element in controlling the duration of a drug's effect. For this reason, different forms of the same medication can have the same active ingredients but different dissolution rates.
In a dissolution process, a solute is changed from a pure phase—solid, liquid, or gas—to a solution phase. If the pure phase of the solute is a solid or gas (presuming the solvent itself is liquid), the process can be seen in two stages: the phase change into a liquid, and the mixing of liquids. The dissolution process is generally ...
For example, by comparing the absorbance values of a solution with an unknown concentration to a series of standard solutions with varying concentrations, the concentration of the unknown can be determined using Beer's Law. Any form of spectroscopy can be used in this way so long as the analyte species has substantial absorbance in the spectra ...
Gravimetric analysis describes a set of methods used in analytical chemistry for the quantitative determination of an analyte (the ion being analyzed) based on its mass. The principle of this type of analysis is that once an ion's mass has been determined as a unique compound, that known measurement can then be used to determine the same analyte's mass in a mixture, as long as the relative ...
ASTM D5773, Standard Test Method of Cloud Point of Petroleum Products (Constant Cooling Rate Method) is an alternative to the manual test procedure. It uses automatic apparatus and has been found to be equivalent to test method D2500. [4] The D5773 test method determines the cloud point in a shorter period of time than manual method D2500.
A serial dilution is the step-wise dilution of a substance in solution, either by using a constant dilution factor, or by using a variable factor between dilutions. If the dilution factor at each step is constant, this results in a geometric progression of the concentration in a logarithmic fashion.