enow.com Web Search

  1. Ad

    related to: high frequency test cable replacement procedure step by step

Search results

  1. Results from the WOW.Com Content Network
  2. Bell System Practices - Wikipedia

    en.wikipedia.org/wiki/Bell_System_Practices

    The content could be general descriptive information, information on wiring and connections, test procedures, or piece-part replacement and repair information. The BSP documents were produced in primarily two formats, 8 1/2"x11" pages for use in office environments, and in a small, portable format (4" x 6 7/8") for use by installers on the job ...

  3. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    Frequency ranges used are within the range of 0.01 Hz to 0.1 Hz, where frequency selection depends on the load presented by the cable. Test voltage levels are either calculated using a multiple of the cable's nominal phase-phase voltage or via tables in IEEE 400.2; typically they are in the range of 1.5 U0 to 3 U0.

  4. Ultrasonic testing - Wikipedia

    en.wikipedia.org/wiki/Ultrasonic_testing

    Step 2: Instrument settings are input. Step 3: The probe is scanned over the blade root. In this case, an indication (peak in the data) through the red line (or gate) indicates a good blade; an indication to the left of that range indicates a crack. Principle of ultrasonic testing. LEFT: A probe sends a sound wave into a test material.

  5. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    An insulation test set; in this pattern, a hand-cranked generator provides the high voltage and the scale is directly calibrated in megohms. Voltage withstand testing is done with a high-voltage source and voltage and current meters. A single instrument called a "pressure test set" or "hipot tester" is often used to perform this test.

  6. Cable fault location - Wikipedia

    en.wikipedia.org/wiki/Cable_fault_location

    Murray loop test employs the principle of wheatstone bridge for locating the fault. To perform this test, it is necessary to have a sound cable running alongside the faulty cable. One end of the faulted cable is connected through a pair of resistors to the voltage source. Also a null detector is connected. The other end of the cable is shorted.

  7. Copper cable certification - Wikipedia

    en.wikipedia.org/wiki/Copper_cable_certification

    The significance of each category or class is the limit values of which the Pass/Fail and frequency ranges are measured: Cat 3 and Class C (no longer used) test and define communication with 16 MHz bandwidth, Cat 5e and Class D with 100 MHz bandwidth, Cat 6 and Class E up to 250 MHz, Cat6A and Class EA up to 500 MHz, Cat7 and Class F up to 600 ...

  8. Cable tester - Wikipedia

    en.wikipedia.org/wiki/Cable_tester

    A cable tester is an electronic device used to verify the electrical connections in a signal cable or other wired assembly. Basic cable testers are continuity testers that verify the existence of a conductive path between ends of the cable, and verify the correct wiring of connectors on the cable. More advanced cable testers can measure the ...

  9. Two-tone testing - Wikipedia

    en.wikipedia.org/wiki/Two-tone_testing

    However, the greater frequency difference between the wanted and unwanted signal makes out-of-band intermodulation products relatively easy to remove with filters. [15] Just as two tones provide a more realistic test than a single tone, multi-tone testing can be used to even better simulate the behaviour of a real signal.

  1. Ad

    related to: high frequency test cable replacement procedure step by step