In the case of an ideal lossless fan system (i.e. =) the SFP is exactly equal to the fan pressure rise (i.e. total pressure loss in the ventilation system). In reality the fan system efficiency is often in the range 0 to 60% (i.e. η t o t < 0.6 {\displaystyle \eta _{tot}<0.6} ); it is lowest for small fans or inefficient operating points (e.g ...
An axial fan is a type of fan that causes gas to flow through it in an axial direction, parallel to the shaft about which the blades rotate. The flow is axial at entry and exit. The fan is designed to produce a pressure difference, and hence force, to cause a flow through the fan. Factors which determine the performance of the fan include the ...
A low pressure ratio fan (such as that used on a high bypass ratio turbofan) has a range of working lines. At high flight speeds, the ram pressure ratio factors up the cold nozzle pressure ratio, causing the nozzle to choke. Above the choking condition, the working lines tend to coalesce into a unique steep straight line.
The affinity laws (also known as the "Fan Laws" or "Pump Laws") for pumps/fans are used in hydraulics, hydronics and/or HVAC to express the relationship between variables involved in pump or fan performance (such as head, volumetric flow rate, shaft speed) and power. They apply to pumps, fans, and hydraulic turbines. In these rotary implements ...
At least one author takes a different approach in order to avoid a need for the expression freestream static pressure. Gracey has written "The static pressure is the atmospheric pressure at the flight level of the aircraft". [15] [16] Gracey then refers to the air pressure at any point close to the aircraft as the local static pressure.
It applies to a fan or other air moving device when air is used as the test gas with the following exceptions: (a) air circulating fans (ceiling fans, desk fans); (b) positive pressure ventilators; (c) compressors with inter-stage cooling; (d) positive displacement machines; (e) test procedures to be used for design, production, or field testing.
is the static pressure at the point at which pressure coefficient is being evaluated is the static pressure in the freestream (i.e. remote from any disturbance) is the freestream fluid density (Air at sea level and 15 °C is 1.225 /)
Vaneaxial fans – These axial flow fans have a higher pressure capability due to the presence of static vanes. Variable pitch axial fans – The blades on these axial fans are manually adjustable to permit the blade angle to be changed. This allows operation over a much wider range of volume/pressure relationships.