Vapor Pressure Deficit (VPD) = Saturation Vapor Pressure (ES) – Actual Vapor Pressure (EA). Below is R code for estimating VPD using mean minimum and maximum monthly temperatures and mean monthly relative humidity according to Allen et al. (1998).
The dew point is the temperature at which the air is saturated (vapour pressure equals saturation vapour pressure). Therefore, to calculate the dew point, you fundamentally need to know both the temperature and some measure for the amount of water vapour contained by the air, be it relative humidity, specific humidity, water vapour partial ...
Vapor pressure is a function of temperature only. Google "Antoine Equation". Best I can suggest is a psychrometric chart with p = RT/v, v = specific volume. R = 0.286 kJ/kg/K and is NOT the familiar universal constant R = 8.31 J/mole/K. Psychrometric chart for air.
The Antoine equation will allow you to calculate the vapor pressure of water at a given temperature, which will allow you to calculate the partial pressure of water at 100% relative humidity. Multiplying this partial pressure by the relative humidity will provide the actual partial pressure of water vapor at the given relative humidity.
1. The equilibrium vapor pressure P of liquid water at a temperature T can be accurately estimated using the Tetens equation: P = 0.61078 exp(17.27 T T + 237.3) If mv is the total mass of the water vapor in the container, then I believe that mv will be a function of the diameter D, h, P, T, and ˙Q.
According to Wikipedia, the Arden Buck Equation is the most accurate formula to calculate the saturated water vapor pressure for a given temperature. Using this fact I came up with the following way to. calculate the dew-point: Calculate saturated water vapor pressure for current temperature using the Arden Buck Equation.
The pressure in the tank will be directly proportional to the outside temperature. At very high outside temperatures the regulator may fail. The pressure on the gauge is not a direct measure of the volume of gas in the tank - since part of the volume may be liquid and part volume may be gas . $\endgroup$ –
There, it is explained that: Based on the Ideal Gas Law, the humidity ratio can be expressed as: x = 0.62198 pw / (pa - pw) where. pw = partial pressure of water vapor in moist air (Pa, psi) pa = atmospheric pressure of moist air (Pa, psi) However, it is very unclear to me where they got the value 0.62198 from.
2. Relative humidity is just the percentage of what the air at a given temperature can hold. This is given by the Clausius–Clapeyron equation, which rises roughly exponentially with temperature doubling approx every 10degrees C. So if your relative humidity is X, and the saturation vapor pressure at the new temperature is Y times the value at ...
My starting point is that the pressure the liquid is experiencing is the sum of the vapor pressure and the non-condensible gas pressure, instead of just the vapor pressure as in the normal case $\endgroup$