enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Rotolock valve - Wikipedia

    en.wikipedia.org/wiki/Rotolock_valve

    Specialized versions are made for specific purposes, such as the Rotolock valve (a stem-type valve also called a Rotalock valve [3]), which is a special refrigeration valve with a teflon ring seated against a machined surface enclosed by a threaded fitting; this valve allows the technician to remove all refrigerant from the compressor without ...

  3. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...

  4. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...

  5. Isolation valve - Wikipedia

    en.wikipedia.org/wiki/Isolation_valve

    An isolation valve is a valve in a fluid handling system that stops the flow of process media to a given location, usually for maintenance or safety purposes. [1] They can also be used to provide flow logic (selecting one flow path versus another), and to connect external equipment to a system. [2]

  6. Schlenk line - Wikipedia

    en.wikipedia.org/wiki/Schlenk_line

    A Schlenk line with four ports. The cold trap is on the right. Close-up view, showing the double-oblique stopcock, which allows vacuum (rear line) or inert gas (front line) to be selected. The Schlenk line (also vacuum gas manifold) is a commonly used chemistry apparatus developed by Wilhelm Schlenk. [1] It consists of a dual manifold with ...

  7. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    In general, valves nearest to the boiler should vent the slowest, and valves furthest from the boiler should vent the fastest. [citation needed] Ideally, steam should reach each valve and close each and every valve at the same time, so that the system can work at maximal efficiency; this condition is known as a "balanced" system. [citation needed]

  8. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Larger buildings, such as offices or hospitals, have more complicated heating and cooling systems and require a more accurate balancing technique. To obtain a plant with the correct design flows, consultants design systems to include balancing valves, differential pressure controllers or pressure independent control valves.

  9. Environmental control system - Wikipedia

    en.wikipedia.org/wiki/Environmental_control_system

    The primary component for the functioning of the cold air unit (CAU) is the Air Cycle Machine (ACM) cooling device. Some aircraft, including early Boeing 707 aircraft, used vapor-compression refrigeration like that used in home air conditioners. An ACM uses no Freon: the air itself is the refrigerant. The ACM is preferred over vapor cycle ...