Commonly used for ASME pressure vessels, these torispherical heads have a crown radius equal to the outside diameter of the head (=), and a knuckle radius equal to 6% of the outside diameter (=). The ASME design code does not allow the knuckle radius to be any less than 6% of the outside diameter.
The first edition of the Boiler and Pressure Vessel Code, known as the 1914 edition, was a single 114-page volume. [ 6 ] [ 7 ] It developed over time into the ASME Boiler and Pressure Vessel code, which today has over 92,000 copies in use, in over 100 countries around the world. [ 5 ]
The ASME definition of a pressure vessel is a container designed to hold gases or liquids at a pressure substantially different from the ambient pressure. [2]The Australian and New Zealand standard "AS/NZS 1200:2000 Pressure equipment" defines a pressure vessel as a vessel subject to internal or external pressure, including connected components and accessories up to the connection to external ...
A typical pressure vessel is not defined until there is at least one atmosphere (14.7 psig) of contained gas pressure. Less than that is typically a storage tank, even if there is some overpressure added by design. The rules for PVHO are invoked at 2 psig (13.8 kPa), per Section 1-2.1 "Application" of the ASME PVHO-1 code. [2]
In fluid dynamics, head is a concept that relates the energy in an incompressible fluid to the height of an equivalent static column of that fluid. From Bernoulli's principle, the total energy at a given point in a fluid is the kinetic energy associated with the speed of flow of the fluid, plus energy from static pressure in the fluid, plus energy from the height of the fluid relative to an ...
Maximum Allowable Operating Pressure (MAOP) is a pressure limit set, usually by a government body, which applies to compressed gas pressure vessels, pipelines, and storage tanks. For pipelines, this value is derived from Barlow's Formula , which takes into account wall thickness, diameter, allowable stress (which is a function of the material ...
Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.
Advantages include: ability to direct flow to certain portions of the jacket, such as only the bottom head when minimal heating or cooling is needed and the entire jacket when maximum heating or cooling is required; ability to provide a higher volume of flow overall (zones are piped in parallel) because the pressure drop through a zone is lower ...