enow.com Web Search

  1. Ads

    related to: replacing electric fuse box switch for generator circuit

Search results

  1. Results from the WOW.Com Content Network
  2. Fuse cutout - Wikipedia

    en.wikipedia.org/wiki/Fuse_cutout

    In electrical distribution, a fuse cutout or cut-out fuse (often referred to as a cutout) is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to ...

  3. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.

  4. Fuse (electrical) - Wikipedia

    en.wikipedia.org/wiki/Fuse_(electrical)

    In electronics and electrical engineering, a fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby stopping or interrupting the current.

  5. Generator interlock kit - Wikipedia

    en.wikipedia.org/wiki/Generator_Interlock_Kit

    A generator interlock kit (or a transfer switch), eliminates the need for extension cords to power appliances. [2]Like a transfer switch, an interlock kit lets the generator energize the panel and all of its circuits (up to the load capacity of the generator); not just corded appliances.

  6. Sulfur hexafluoride circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Sulfur_hexafluoride...

    Generator circuit breaker rated for 17.5 kV and 63 kA. Generator circuit breakers (GCB) are connected between a generator and the step-up voltage transformer. They are generally used at the outlet of high-power generators (30 MVA to 1800 MVA) in order to protect them in a reliable, fast and economic manner.

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  8. Knob-and-tube wiring - Wikipedia

    en.wikipedia.org/wiki/Knob-and-tube_wiring

    However, most existing residential knob-and-tube installations, dating to before 1940, have fewer branch circuits than is desired today. While these installations were adequate for the electrical loads at the time of installation, modern households use a range and intensity of electrical equipment unforeseen at the time.

  9. IEC 60269 - Wikipedia

    en.wikipedia.org/wiki/IEC_60269

    In electrical engineering, IEC 60269 is a set of technical standards for low-voltage power fuses. [1] The standard is in four volumes, which describe general requirements, fuses for industrial and commercial applications, fuses for residential applications, and fuses to protect semiconductor devices.

  1. Ads

    related to: replacing electric fuse box switch for generator circuit