enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. IEC 60446 - Wikipedia

    en.wikipedia.org/wiki/IEC_60446

    The international standard IEC 60446 Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors was a standard published by the International Electrotechnical Commission (IEC) that defined basic safety principles for identifying electrical conductors by colours or numerals, for example in ...

  3. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...

  4. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  5. Electrical wiring in the United Kingdom - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_the...

    Household wiring does not usually use three-phase supplies and the clash only occurs in three-phase systems. Wiring to the old standard can be detected by use of a red wire. The new standard colour code does not use red. Where new wiring is mixed with old, cables must be clearly marked to prevent interchange of phase and neutral.

  6. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase. Since these two modes do not need three phases there is also a dark yellow-orange four-pin connector available designed for a single-phase 110–120 or 220–240 volt load.

  7. BS 7671 - Wikipedia

    en.wikipedia.org/wiki/BS_7671

    The cable core colours are described in IEC 60304 (1982-01), Standard colours for insulation for low- frequency cables and wires. The three-phase phase colours are brown, black and grey instead of red, yellow and blue. Where a circuit includes a neutral or mid-point conductor identified by colour, the colour used shall be blue.

  8. Electrical code - Wikipedia

    en.wikipedia.org/wiki/Electrical_code

    Cable identification colours: [f] (section 3.8.3.4) Multiphase cables [d] Current AS/NZS cables European cables Single-phase cables Current AS/NZS flexible cords, flexible cables and equipment wiring, and European cables Superseded AS/NZS flexible cords Pre-2004 IEE [further explanation needed] United Kingdom until April 2006 (BS 7671) India ...

  9. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A.