  2. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    High-leg delta (also known as wild-leg, stinger leg, bastard leg, high-leg, orange-leg, red-leg, dog-leg delta) is a type of electrical service connection for three-phase electric power installations. It is used when both single and three-phase power is desired to be supplied from a three phase transformer (or transformer bank).

  3. Grounding transformer - Wikipedia

    en.wikipedia.org/wiki/Grounding_transformer

    A grounding transformer or earthing transformer is a type of auxiliary transformer used in three-phase electric power systems to provide a ground path to either an ungrounded wye or a delta-connected system. [1] [2] Grounding transformers are part of an earthing system of the network.

  4. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    The purpose of a zigzag transformer in this application is to provide a return path for earth faults on delta-connected systems. With negligible current in the neutral under normal conditions, an undersized (unable to carry a continuous fault load) transformer may be used only as short-time rating is required, provided the defective load will ...

  5. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.

  6. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    The delta winding allows third-harmonic currents to circulate within the transformer, and prevents third-harmonic currents from flowing in the supply line. [2] Delta-wye transformers introduce a 30, 150, 210, or 330 degree phase shift. [3] Thus they cannot be paralleled with wye-wye (or delta-delta) transformers.

  7. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    To prevent electric power distribution network damage, each station along the network is protected with circuit breakers or fuse cutouts which turn off power in the event of a short circuit. These protection solutions present a major problem when restoring power immediately following transient events, because repair crews need to manually reset ...

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    In an electric arc furnace, the transformer has a heavy copper bus for the low voltage winding, which can be rated for tens of thousands of amperes.Winding beginnings and ends are led out separately and "interleaved" for the external delta closure in a Knapsack connection. [1]