enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Buck–boost transformer - Wikipedia

    en.wikipedia.org/wiki/Buck–boost_transformer

    Buck–boost transformers can be used to power low voltage circuits including control, lighting circuits, or applications that require 12, 16, 24, 32 or 48 volts, consistent with the design's secondaries. The transformer is connected as an isolating transformer and the nameplate kVA rating is the transformer’s capacity. [2]

  3. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    After reaching the rated current of the HV side, all three instruments reading (Voltmeter, Ammeter, and wattmeter readings) are recorded. The ammeter reading gives the primary equivalent of full load current I L. As the voltage applied for full load current in short circuit test on transformer is quite small compared to the rated primary ...

  4. Polarity (mutual inductance) - Wikipedia

    en.wikipedia.org/wiki/Polarity_(mutual_inductance)

    Transformers are said to have "additive" or "subtractive" polarity based on their physical arrangement of terminals and the polarity of windings connected to the terminals. The convention used for North American transformers is that, facing the high voltage side of the transformer, the H1 terminal is on the observer's right.

  5. Current transformer - Wikipedia

    en.wikipedia.org/wiki/Current_transformer

    A high-voltage current transformer may contain several cores, each with a secondary winding, for different purposes (such as metering circuits, control, or protection). [7] A neutral current transformer is used as earth fault protection to measure any fault current flowing through the neutral line from the wye neutral point of a transformer.

  6. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units.

  7. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    A current transformer (CT) is a series connected measurement device designed to provide a current in its secondary coil proportional to the current flowing in its primary. Current transformers are commonly used in metering and protective relays in the electrical power industry.

  8. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The neutral current can be determined by adding the three phase currents together as complex numbers and then converting from rectangular to polar co-ordinates. If the three-phase root mean square (RMS) currents are I L 1 {\displaystyle I_{L1}} , I L 2 {\displaystyle I_{L2}} , and I L 3 {\displaystyle I_{L3}} , the neutral RMS current is:

  9. Copper loss - Wikipedia

    en.wikipedia.org/wiki/Copper_loss

    For low-frequency applications, the power loss can be minimized by employing conductors with a large cross-sectional area, made from low-resistivity metals.With high-frequency currents, the proximity effect and skin effect cause the current to be unevenly distributed across the conductor, increasing its effective resistance, and making loss calculations more difficult.