Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [ 1 ]
The design of the flame ionization detector varies from manufacturer to manufacturer, but the principles are the same. Most commonly, the FID is attached to a gas chromatography system. The eluent exits the gas chromatography column (A) and enters the FID detector’s oven (B). The oven is needed to make sure that as soon as the eluent exits ...
Electron capture detector developed by James Lovelock in the Science Museum, London Electron capture detector, Science History Institute. The electron capture detector is used for detecting electron-absorbing components (high electronegativity) such as halogenated compounds in the output stream of a gas chromatograph.
The mass spectrometry process normally requires a very pure sample while gas chromatography using a traditional detector (e.g. Flame ionization detector) cannot differentiate between multiple molecules that happen to take the same amount of time to travel through the column (i.e. have the same retention time), which results in two or more ...
The following other wikis use this file: Usage on ar.wikipedia.org استشراب غازي; Usage on bs.wikipedia.org Gasna hromatografija; Usage on en.wikibooks.org
Many gas chromatograph detectors are ion detectors with varying methods of ionizing the components eluting from the gas chromatograph's column. [1] [2] An ion detector is analogous to a capacitor or vacuum tube. It can be envisioned as two metal grids separated by air with inverse charges placed on them.
The thermal conductivity detector (TCD), also known as a katharometer, is a bulk property detector and a chemical specific detector commonly used in gas chromatography. [1] This detector senses changes in the thermal conductivity of the column eluent and compares it to a reference flow of carrier gas. Since most compounds have a thermal ...
Therefore, this mode requires that the gas stream grazes the sample surface and does not block gas flow to the mass spectrometer sampling orifice. In contrast, transmission mode DART (tm-DART) uses a custom-made sample holder and introduces the sample at a fixed geometry. [10] [13] Schematic diagram of DART-transmission mode